rjw | 1f88458 | 2022-01-06 17:20:42 +0800 | [diff] [blame^] | 1 | # arch/arm/mach-s3c24xx/Kconfig |
| 2 | # |
| 3 | # Copyright (c) 2012 Samsung Electronics Co., Ltd. |
| 4 | # http://www.samsung.com/ |
| 5 | # |
| 6 | # Copyright 2007 Simtec Electronics |
| 7 | # |
| 8 | # Licensed under GPLv2 |
| 9 | |
| 10 | if ARCH_S3C24XX |
| 11 | |
| 12 | config PLAT_S3C24XX |
| 13 | def_bool y |
| 14 | select GPIOLIB |
| 15 | select NO_IOPORT_MAP |
| 16 | select S3C_DEV_NAND |
| 17 | select IRQ_DOMAIN |
| 18 | select COMMON_CLK |
| 19 | help |
| 20 | Base platform code for any Samsung S3C24XX device |
| 21 | |
| 22 | |
| 23 | |
| 24 | menu "SAMSUNG S3C24XX SoCs Support" |
| 25 | |
| 26 | comment "S3C24XX SoCs" |
| 27 | |
| 28 | config CPU_S3C2410 |
| 29 | bool "SAMSUNG S3C2410" |
| 30 | default y |
| 31 | select CPU_ARM920T |
| 32 | select S3C2410_COMMON_CLK |
| 33 | select ARM_S3C2410_CPUFREQ if ARM_S3C24XX_CPUFREQ |
| 34 | select S3C2410_PM if PM |
| 35 | help |
| 36 | Support for S3C2410 and S3C2410A family from the S3C24XX line |
| 37 | of Samsung Mobile CPUs. |
| 38 | |
| 39 | config CPU_S3C2412 |
| 40 | bool "SAMSUNG S3C2412" |
| 41 | select CPU_ARM926T |
| 42 | select S3C2412_COMMON_CLK |
| 43 | select S3C2412_PM if PM_SLEEP |
| 44 | help |
| 45 | Support for the S3C2412 and S3C2413 SoCs from the S3C24XX line |
| 46 | |
| 47 | config CPU_S3C2416 |
| 48 | bool "SAMSUNG S3C2416/S3C2450" |
| 49 | select CPU_ARM926T |
| 50 | select S3C2416_PM if PM_SLEEP |
| 51 | select S3C2443_COMMON_CLK |
| 52 | help |
| 53 | Support for the S3C2416 SoC from the S3C24XX line |
| 54 | |
| 55 | config CPU_S3C2440 |
| 56 | bool "SAMSUNG S3C2440" |
| 57 | select CPU_ARM920T |
| 58 | select S3C2410_COMMON_CLK |
| 59 | select S3C2410_PM if PM_SLEEP |
| 60 | help |
| 61 | Support for S3C2440 Samsung Mobile CPU based systems. |
| 62 | |
| 63 | config CPU_S3C2442 |
| 64 | bool "SAMSUNG S3C2442" |
| 65 | select CPU_ARM920T |
| 66 | select S3C2410_COMMON_CLK |
| 67 | select S3C2410_PM if PM_SLEEP |
| 68 | help |
| 69 | Support for S3C2442 Samsung Mobile CPU based systems. |
| 70 | |
| 71 | config CPU_S3C244X |
| 72 | def_bool y |
| 73 | depends on CPU_S3C2440 || CPU_S3C2442 |
| 74 | |
| 75 | config CPU_S3C2443 |
| 76 | bool "SAMSUNG S3C2443" |
| 77 | select CPU_ARM920T |
| 78 | select S3C2443_COMMON_CLK |
| 79 | help |
| 80 | Support for the S3C2443 SoC from the S3C24XX line |
| 81 | |
| 82 | # common code |
| 83 | |
| 84 | config S3C24XX_SMDK |
| 85 | bool |
| 86 | help |
| 87 | Common machine code for SMDK2410 and SMDK2440 |
| 88 | |
| 89 | config S3C24XX_SIMTEC_AUDIO |
| 90 | bool |
| 91 | depends on (ARCH_BAST || MACH_VR1000 || MACH_OSIRIS || MACH_ANUBIS) |
| 92 | default y |
| 93 | help |
| 94 | Add audio devices for common Simtec S3C24XX boards |
| 95 | |
| 96 | config S3C24XX_SIMTEC_PM |
| 97 | bool |
| 98 | help |
| 99 | Common power management code for systems that are |
| 100 | compatible with the Simtec style of power management |
| 101 | |
| 102 | config S3C24XX_SIMTEC_USB |
| 103 | bool |
| 104 | help |
| 105 | USB management code for common Simtec S3C24XX boards |
| 106 | |
| 107 | config S3C24XX_SETUP_TS |
| 108 | bool |
| 109 | help |
| 110 | Compile in platform device definition for Samsung TouchScreen. |
| 111 | |
| 112 | config S3C2410_PM |
| 113 | bool |
| 114 | help |
| 115 | Power Management code common to S3C2410 and better |
| 116 | |
| 117 | config S3C24XX_PLL |
| 118 | bool "Support CPUfreq changing of PLL frequency (EXPERIMENTAL)" |
| 119 | depends on ARM_S3C24XX_CPUFREQ |
| 120 | help |
| 121 | Compile in support for changing the PLL frequency from the |
| 122 | S3C24XX series CPUfreq driver. The PLL takes time to settle |
| 123 | after a frequency change, so by default it is not enabled. |
| 124 | |
| 125 | This also means that the PLL tables for the selected CPU(s) will |
| 126 | be built which may increase the size of the kernel image. |
| 127 | |
| 128 | config S3C_SETUP_CAMIF |
| 129 | bool |
| 130 | help |
| 131 | Compile in common setup code for S3C CAMIF devices |
| 132 | |
| 133 | # cpu frequency items common between s3c2410 and s3c2440/s3c2442 |
| 134 | |
| 135 | config S3C2410_IOTIMING |
| 136 | bool |
| 137 | depends on ARM_S3C24XX_CPUFREQ |
| 138 | help |
| 139 | Internal node to select io timing code that is common to the s3c2410 |
| 140 | and s3c2440/s3c2442 cpu frequency support. |
| 141 | |
| 142 | config S3C2410_CPUFREQ_UTILS |
| 143 | bool |
| 144 | depends on ARM_S3C24XX_CPUFREQ |
| 145 | help |
| 146 | Internal node to select timing code that is common to the s3c2410 |
| 147 | and s3c2440/s3c244 cpu frequency support. |
| 148 | |
| 149 | # cpu frequency support common to s3c2412, s3c2413 and s3c2442 |
| 150 | |
| 151 | config S3C2412_IOTIMING |
| 152 | bool |
| 153 | depends on ARM_S3C24XX_CPUFREQ && (CPU_S3C2412 || CPU_S3C2443) |
| 154 | help |
| 155 | Intel node to select io timing code that is common to the s3c2412 |
| 156 | and the s3c2443. |
| 157 | |
| 158 | # cpu-specific sections |
| 159 | |
| 160 | if CPU_S3C2410 |
| 161 | |
| 162 | config S3C2410_PLL |
| 163 | bool |
| 164 | depends on ARM_S3C2410_CPUFREQ && S3C24XX_PLL |
| 165 | default y |
| 166 | help |
| 167 | Select the PLL table for the S3C2410 |
| 168 | |
| 169 | config S3C24XX_SIMTEC_NOR |
| 170 | bool |
| 171 | help |
| 172 | Internal node to specify machine has simtec NOR mapping |
| 173 | |
| 174 | config MACH_BAST_IDE |
| 175 | bool |
| 176 | select HAVE_PATA_PLATFORM |
| 177 | help |
| 178 | Internal node for machines with an BAST style IDE |
| 179 | interface |
| 180 | |
| 181 | comment "S3C2410 Boards" |
| 182 | |
| 183 | # |
| 184 | # The "S3C2410 Boards" list is ordered alphabetically by option text. |
| 185 | # (without ARCH_ or MACH_) |
| 186 | # |
| 187 | |
| 188 | config MACH_AML_M5900 |
| 189 | bool "AML M5900 Series" |
| 190 | select S3C24XX_SIMTEC_PM if PM |
| 191 | select S3C_DEV_USB_HOST |
| 192 | help |
| 193 | Say Y here if you are using the American Microsystems M5900 Series |
| 194 | <http://www.amltd.com> |
| 195 | |
| 196 | config ARCH_BAST |
| 197 | bool "Simtec Electronics BAST (EB2410ITX)" |
| 198 | select ISA |
| 199 | select MACH_BAST_IDE |
| 200 | select S3C2410_COMMON_DCLK |
| 201 | select S3C2410_IOTIMING if ARM_S3C2410_CPUFREQ |
| 202 | select S3C24XX_SIMTEC_NOR |
| 203 | select S3C24XX_SIMTEC_PM if PM |
| 204 | select S3C24XX_SIMTEC_USB |
| 205 | select S3C_DEV_HWMON |
| 206 | select S3C_DEV_NAND |
| 207 | select S3C_DEV_USB_HOST |
| 208 | help |
| 209 | Say Y here if you are using the Simtec Electronics EB2410ITX |
| 210 | development board (also known as BAST) |
| 211 | |
| 212 | config BAST_PC104_IRQ |
| 213 | bool "BAST PC104 IRQ support" |
| 214 | depends on ARCH_BAST |
| 215 | default y |
| 216 | help |
| 217 | Say Y here to enable the PC104 IRQ routing on the |
| 218 | Simtec BAST (EB2410ITX) |
| 219 | |
| 220 | config ARCH_H1940 |
| 221 | bool "IPAQ H1940" |
| 222 | select PM_H1940 if PM |
| 223 | select S3C24XX_SETUP_TS |
| 224 | select S3C_DEV_NAND |
| 225 | select S3C_DEV_USB_HOST |
| 226 | help |
| 227 | Say Y here if you are using the HP IPAQ H1940 |
| 228 | |
| 229 | config H1940BT |
| 230 | tristate "Control the state of H1940 bluetooth chip" |
| 231 | depends on ARCH_H1940 |
| 232 | depends on RFKILL |
| 233 | help |
| 234 | This is a simple driver that is able to control |
| 235 | the state of built in bluetooth chip on h1940. |
| 236 | |
| 237 | config MACH_N30 |
| 238 | bool "Acer N30 family" |
| 239 | select S3C_DEV_NAND |
| 240 | select S3C_DEV_USB_HOST |
| 241 | help |
| 242 | Say Y here if you want suppt for the Acer N30, Acer N35, |
| 243 | Navman PiN570, Yakumo AlphaX or Airis NC05 PDAs. |
| 244 | |
| 245 | config MACH_OTOM |
| 246 | bool "NexVision OTOM Board" |
| 247 | select S3C_DEV_NAND |
| 248 | select S3C_DEV_USB_HOST |
| 249 | help |
| 250 | Say Y here if you are using the Nex Vision OTOM board |
| 251 | |
| 252 | config MACH_QT2410 |
| 253 | bool "QT2410" |
| 254 | select S3C_DEV_NAND |
| 255 | select S3C_DEV_USB_HOST |
| 256 | help |
| 257 | Say Y here if you are using the Armzone QT2410 |
| 258 | |
| 259 | config ARCH_SMDK2410 |
| 260 | bool "SMDK2410/A9M2410" |
| 261 | select S3C24XX_SMDK |
| 262 | select S3C_DEV_USB_HOST |
| 263 | help |
| 264 | Say Y here if you are using the SMDK2410 or the derived module A9M2410 |
| 265 | <http://www.fsforth.de> |
| 266 | |
| 267 | config MACH_TCT_HAMMER |
| 268 | bool "TCT Hammer Board" |
| 269 | select S3C_DEV_USB_HOST |
| 270 | help |
| 271 | Say Y here if you are using the TinCanTools Hammer Board |
| 272 | <http://www.tincantools.com> |
| 273 | |
| 274 | config MACH_VR1000 |
| 275 | bool "Thorcom VR1000" |
| 276 | select MACH_BAST_IDE |
| 277 | select S3C2410_COMMON_DCLK |
| 278 | select S3C24XX_SIMTEC_NOR |
| 279 | select S3C24XX_SIMTEC_PM if PM |
| 280 | select S3C24XX_SIMTEC_USB |
| 281 | select S3C_DEV_USB_HOST |
| 282 | help |
| 283 | Say Y here if you are using the Thorcom VR1000 board. |
| 284 | |
| 285 | endif # CPU_S3C2410 |
| 286 | |
| 287 | config S3C2412_PM_SLEEP |
| 288 | bool |
| 289 | help |
| 290 | Internal config node to apply sleep for S3C2412 power management. |
| 291 | Can be selected by another SoCs such as S3C2416 with similar |
| 292 | sleep procedure. |
| 293 | |
| 294 | if CPU_S3C2412 |
| 295 | |
| 296 | config CPU_S3C2412_ONLY |
| 297 | bool |
| 298 | depends on !CPU_S3C2410 && !CPU_S3C2416 && !CPU_S3C2440 && \ |
| 299 | !CPU_S3C2442 && !CPU_S3C2443 |
| 300 | default y |
| 301 | |
| 302 | config S3C2412_PM |
| 303 | bool |
| 304 | select S3C2412_PM_SLEEP |
| 305 | select SAMSUNG_WAKEMASK |
| 306 | help |
| 307 | Internal config node to apply S3C2412 power management |
| 308 | |
| 309 | comment "S3C2412 Boards" |
| 310 | |
| 311 | # |
| 312 | # The "S3C2412 Boards" list is ordered alphabetically by option text. |
| 313 | # (without ARCH_ or MACH_) |
| 314 | # |
| 315 | |
| 316 | config MACH_JIVE |
| 317 | bool "Logitech Jive" |
| 318 | select S3C_DEV_NAND |
| 319 | select S3C_DEV_USB_HOST |
| 320 | help |
| 321 | Say Y here if you are using the Logitech Jive. |
| 322 | |
| 323 | config MACH_JIVE_SHOW_BOOTLOADER |
| 324 | bool "Allow access to bootloader partitions in MTD" |
| 325 | depends on MACH_JIVE |
| 326 | |
| 327 | config MACH_S3C2413 |
| 328 | bool |
| 329 | help |
| 330 | Internal node for S3C2413 version of SMDK2413, so that |
| 331 | machine_is_s3c2413() will work when MACH_SMDK2413 is |
| 332 | selected |
| 333 | |
| 334 | config MACH_SMDK2412 |
| 335 | bool "SMDK2412" |
| 336 | select MACH_SMDK2413 |
| 337 | help |
| 338 | Say Y here if you are using an SMDK2412 |
| 339 | |
| 340 | Note, this shares support with SMDK2413, so will automatically |
| 341 | select MACH_SMDK2413. |
| 342 | |
| 343 | config MACH_SMDK2413 |
| 344 | bool "SMDK2413" |
| 345 | select MACH_S3C2413 |
| 346 | select S3C24XX_SMDK |
| 347 | select S3C_DEV_NAND |
| 348 | select S3C_DEV_USB_HOST |
| 349 | help |
| 350 | Say Y here if you are using an SMDK2413 |
| 351 | |
| 352 | config MACH_VSTMS |
| 353 | bool "VMSTMS" |
| 354 | select S3C_DEV_NAND |
| 355 | select S3C_DEV_USB_HOST |
| 356 | help |
| 357 | Say Y here if you are using an VSTMS board |
| 358 | |
| 359 | endif # CPU_S3C2412 |
| 360 | |
| 361 | if CPU_S3C2416 |
| 362 | |
| 363 | config S3C2416_PM |
| 364 | bool |
| 365 | select S3C2412_PM_SLEEP |
| 366 | select SAMSUNG_WAKEMASK |
| 367 | help |
| 368 | Internal config node to apply S3C2416 power management |
| 369 | |
| 370 | config S3C2416_SETUP_SDHCI |
| 371 | bool |
| 372 | select S3C2416_SETUP_SDHCI_GPIO |
| 373 | help |
| 374 | Internal helper functions for S3C2416 based SDHCI systems |
| 375 | |
| 376 | config S3C2416_SETUP_SDHCI_GPIO |
| 377 | bool |
| 378 | help |
| 379 | Common setup code for SDHCI gpio. |
| 380 | |
| 381 | comment "S3C2416 Boards" |
| 382 | |
| 383 | config MACH_SMDK2416 |
| 384 | bool "SMDK2416" |
| 385 | select S3C2416_SETUP_SDHCI |
| 386 | select S3C24XX_SMDK |
| 387 | select S3C_DEV_FB |
| 388 | select S3C_DEV_HSMMC |
| 389 | select S3C_DEV_HSMMC1 |
| 390 | select S3C_DEV_NAND |
| 391 | select S3C_DEV_USB_HOST |
| 392 | help |
| 393 | Say Y here if you are using an SMDK2416 |
| 394 | |
| 395 | config MACH_S3C2416_DT |
| 396 | bool "Samsung S3C2416 machine using devicetree" |
| 397 | select TIMER_OF |
| 398 | select USE_OF |
| 399 | select PINCTRL |
| 400 | select PINCTRL_S3C24XX |
| 401 | help |
| 402 | Machine support for Samsung S3C2416 machines with device tree enabled. |
| 403 | Select this if a fdt blob is available for the S3C2416 SoC based board. |
| 404 | Note: This is under development and not all peripherals can be supported |
| 405 | with this machine file. |
| 406 | |
| 407 | endif # CPU_S3C2416 |
| 408 | |
| 409 | if CPU_S3C2440 || CPU_S3C2442 |
| 410 | |
| 411 | config S3C2440_XTAL_12000000 |
| 412 | bool |
| 413 | help |
| 414 | Indicate that the build needs to support 12MHz system |
| 415 | crystal. |
| 416 | |
| 417 | config S3C2440_XTAL_16934400 |
| 418 | bool |
| 419 | help |
| 420 | Indicate that the build needs to support 16.9344MHz system |
| 421 | crystal. |
| 422 | |
| 423 | config S3C2440_PLL_12000000 |
| 424 | bool |
| 425 | depends on ARM_S3C2440_CPUFREQ && S3C2440_XTAL_12000000 |
| 426 | default y if S3C24XX_PLL |
| 427 | help |
| 428 | PLL tables for S3C2440 or S3C2442 CPUs with 12MHz crystals. |
| 429 | |
| 430 | config S3C2440_PLL_16934400 |
| 431 | bool |
| 432 | depends on ARM_S3C2440_CPUFREQ && S3C2440_XTAL_16934400 |
| 433 | default y if S3C24XX_PLL |
| 434 | help |
| 435 | PLL tables for S3C2440 or S3C2442 CPUs with 16.934MHz crystals. |
| 436 | endif |
| 437 | |
| 438 | if CPU_S3C2440 |
| 439 | |
| 440 | comment "S3C2440 Boards" |
| 441 | |
| 442 | # |
| 443 | # The "S3C2440 Boards" list is ordered alphabetically by option text. |
| 444 | # (without ARCH_ or MACH_) |
| 445 | # |
| 446 | |
| 447 | config MACH_ANUBIS |
| 448 | bool "Simtec Electronics ANUBIS" |
| 449 | select HAVE_PATA_PLATFORM |
| 450 | select S3C2410_COMMON_DCLK |
| 451 | select S3C2440_XTAL_12000000 |
| 452 | select S3C24XX_SIMTEC_PM if PM |
| 453 | select S3C_DEV_USB_HOST |
| 454 | help |
| 455 | Say Y here if you are using the Simtec Electronics ANUBIS |
| 456 | development system |
| 457 | |
| 458 | config MACH_AT2440EVB |
| 459 | bool "Avantech AT2440EVB development board" |
| 460 | select S3C_DEV_NAND |
| 461 | select S3C_DEV_USB_HOST |
| 462 | help |
| 463 | Say Y here if you are using the AT2440EVB development board |
| 464 | |
| 465 | config MACH_MINI2440 |
| 466 | bool "MINI2440 development board" |
| 467 | select LEDS_CLASS |
| 468 | select LEDS_TRIGGERS |
| 469 | select LEDS_TRIGGER_BACKLIGHT |
| 470 | select NEW_LEDS |
| 471 | select S3C_DEV_NAND |
| 472 | select S3C_DEV_USB_HOST |
| 473 | select S3C_SETUP_CAMIF |
| 474 | help |
| 475 | Say Y here to select support for the MINI2440. Is a 10cm x 10cm board |
| 476 | available via various sources. It can come with a 3.5" or 7" touch LCD. |
| 477 | |
| 478 | config MACH_NEXCODER_2440 |
| 479 | bool "NexVision NEXCODER 2440 Light Board" |
| 480 | select S3C2440_XTAL_12000000 |
| 481 | select S3C_DEV_NAND |
| 482 | select S3C_DEV_USB_HOST |
| 483 | help |
| 484 | Say Y here if you are using the Nex Vision NEXCODER 2440 Light Board |
| 485 | |
| 486 | config MACH_OSIRIS |
| 487 | bool "Simtec IM2440D20 (OSIRIS) module" |
| 488 | select S3C2410_COMMON_DCLK |
| 489 | select S3C2410_IOTIMING if ARM_S3C2440_CPUFREQ |
| 490 | select S3C2440_XTAL_12000000 |
| 491 | select S3C24XX_SIMTEC_PM if PM |
| 492 | select S3C_DEV_NAND |
| 493 | select S3C_DEV_USB_HOST |
| 494 | help |
| 495 | Say Y here if you are using the Simtec IM2440D20 module, also |
| 496 | known as the Osiris. |
| 497 | |
| 498 | config MACH_OSIRIS_DVS |
| 499 | tristate "Simtec IM2440D20 (OSIRIS) Dynamic Voltage Scaling driver" |
| 500 | depends on MACH_OSIRIS |
| 501 | depends on TPS65010 |
| 502 | help |
| 503 | Say Y/M here if you want to have dynamic voltage scaling support |
| 504 | on the Simtec IM2440D20 (OSIRIS) module via the TPS65011. |
| 505 | |
| 506 | The DVS driver alters the voltage supplied to the ARM core |
| 507 | depending on the frequency it is running at. The driver itself |
| 508 | does not do any of the frequency alteration, which is left up |
| 509 | to the cpufreq driver. |
| 510 | |
| 511 | config MACH_RX3715 |
| 512 | bool "HP iPAQ rx3715" |
| 513 | select PM_H1940 if PM |
| 514 | select S3C2440_XTAL_16934400 |
| 515 | select S3C_DEV_NAND |
| 516 | help |
| 517 | Say Y here if you are using the HP iPAQ rx3715. |
| 518 | |
| 519 | config ARCH_S3C2440 |
| 520 | bool "SMDK2440" |
| 521 | select S3C2440_XTAL_16934400 |
| 522 | select S3C24XX_SMDK |
| 523 | select S3C_DEV_NAND |
| 524 | select S3C_DEV_USB_HOST |
| 525 | help |
| 526 | Say Y here if you are using the SMDK2440. |
| 527 | |
| 528 | config SMDK2440_CPU2440 |
| 529 | bool "SMDK2440 with S3C2440 CPU module" |
| 530 | default y if ARCH_S3C2440 |
| 531 | select S3C2440_XTAL_16934400 |
| 532 | |
| 533 | endif # CPU_S3C2440 |
| 534 | |
| 535 | if CPU_S3C2442 |
| 536 | |
| 537 | comment "S3C2442 Boards" |
| 538 | |
| 539 | # |
| 540 | # The "S3C2442 Boards" list is ordered alphabetically by option text. |
| 541 | # (without ARCH_ or MACH_) |
| 542 | # |
| 543 | |
| 544 | config MACH_NEO1973_GTA02 |
| 545 | bool "Openmoko GTA02 / Freerunner phone" |
| 546 | select I2C |
| 547 | select MFD_PCF50633 |
| 548 | select PCF50633_GPIO |
| 549 | select POWER_SUPPLY |
| 550 | select S3C24XX_PWM |
| 551 | select S3C_DEV_USB_HOST |
| 552 | help |
| 553 | Say Y here if you are using the Openmoko GTA02 / Freerunner GSM Phone |
| 554 | |
| 555 | config MACH_RX1950 |
| 556 | bool "HP iPAQ rx1950" |
| 557 | select I2C |
| 558 | select PM_H1940 if PM |
| 559 | select S3C2410_COMMON_DCLK |
| 560 | select S3C2410_IOTIMING if ARM_S3C2440_CPUFREQ |
| 561 | select S3C2440_XTAL_16934400 |
| 562 | select S3C24XX_PWM |
| 563 | select S3C_DEV_NAND |
| 564 | help |
| 565 | Say Y here if you're using HP iPAQ rx1950 |
| 566 | |
| 567 | endif # CPU_S3C2442 |
| 568 | |
| 569 | if CPU_S3C2443 || CPU_S3C2416 |
| 570 | |
| 571 | config S3C2443_SETUP_SPI |
| 572 | bool |
| 573 | help |
| 574 | Common setup code for SPI GPIO configurations |
| 575 | |
| 576 | endif # CPU_S3C2443 || CPU_S3C2416 |
| 577 | |
| 578 | if CPU_S3C2443 |
| 579 | |
| 580 | comment "S3C2443 Boards" |
| 581 | |
| 582 | config MACH_SMDK2443 |
| 583 | bool "SMDK2443" |
| 584 | select S3C24XX_SMDK |
| 585 | select S3C_DEV_HSMMC1 |
| 586 | help |
| 587 | Say Y here if you are using an SMDK2443 |
| 588 | |
| 589 | endif # CPU_S3C2443 |
| 590 | |
| 591 | config PM_H1940 |
| 592 | bool |
| 593 | help |
| 594 | Internal node for H1940 and related PM |
| 595 | |
| 596 | endmenu # SAMSUNG S3C24XX SoCs Support |
| 597 | |
| 598 | endif # ARCH_S3C24XX |