ASR_BASE
Change-Id: Icf3719cc0afe3eeb3edc7fa80a2eb5199ca9dda1
diff --git a/external/subpack/net/nut/files/nut-monitor.init b/external/subpack/net/nut/files/nut-monitor.init
new file mode 100755
index 0000000..e57a287
--- /dev/null
+++ b/external/subpack/net/nut/files/nut-monitor.init
@@ -0,0 +1,231 @@
+#!/bin/sh /etc/rc.common
+
+START=82
+STOP=28
+USE_PROCD=1
+UPSMON_C=/var/etc/nut/upsmon.conf
+
+nut_upsmon_conf() {
+ local cfg="$1"
+ local RUNAS val optval
+
+ echo "# Config file automatically generated from UCI config" > "$UPSMON_C"
+
+ config_get RUNAS "$cfg" runas "nutmon"
+ [ -n "$RUNAS" ] && echo "RUN_AS_USER $RUNAS" >> "$UPSMON_C"
+ runas="$RUNAS"
+
+ config_get val "$cfg" minsupplies 1
+ echo "MINSUPPLIES $val" >> "$UPSMON_C"
+
+ config_get val "$cfg" shutdowncmd "/usr/sbin/nutshutdown"
+ echo "SHUTDOWNCMD \"$val\"" >> "$UPSMON_C"
+
+ config_get val "$cfg" notifycmd
+ [ -n "$val" ] && echo "NOTIFYCMD \"$val\"" >> "$UPSMON_C"
+
+ config_get val "$cfg" pollfreq 5
+ echo "POLLFREQ $val" >> "$UPSMON_C"
+
+ config_get val "$cfg" pollfreqalert 5
+ echo "POLLFREQALERT $val" >> "$UPSMON_C"
+
+ config_get val "$cfg" hostsync 15
+ echo "HOSTSYNC $val" >> "$UPSMON_C"
+
+ config_get val "$cfg" deadtime 15
+ echo "DEADTIME $val" >> "$UPSMON_C"
+
+ echo "POWERDOWNFLAG /var/run/killpower" >> "$UPSMON_C"
+
+ config_get val "$cfg" onlinemsg
+ [ -n "$val" ] && echo "NOTIFYMSG ONLINE \"$val\"" >> "$UPSMON_C"
+ config_get val "$cfg" onbattmsg
+ [ -n "$val" ] && echo "NOTIFYMSG ONBATT \"$val\"" >> "$UPSMON_C"
+ config_get val "$cfg" lowbattmsg
+ [ -n "$val" ] && echo "NOTIFYMSG LOWBATT \"$val\"" >> "$UPSMON_C"
+ config_get val "$cfg" fsdmsg
+ [ -n "$val" ] && echo "NOTIFYMSG FSD \"$val\"" >> "$UPSMON_C"
+ config_get val "$cfg" commokmsg
+ [ -n "$val" ] && echo "NOTIFYMSG COMMOK \"$val\"" >> "$UPSMON_C"
+ config_get val "$cfg" commbadmsg
+ [ -n "$val" ] && echo "NOTIFYMSG COMMBAD \"$val\"" >> "$UPSMON_C"
+ config_get val "$cfg" shutdownmsg
+ [ -n "$val" ] && echo "NOTIFYMSG SHUTDOWN \"$val\"" >> "$UPSMON_C"
+ config_get val "$cfg" replbattmsg
+ [ -n "$val" ] && echo "NOTIFYMSG REPLBATT \"$val\"" >> "$UPSMON_C"
+ config_get val "$cfg" nocommmsg
+ [ -n "$val" ] && echo "NOTIFYMSG NOCOMM \"$val\"" >> "$UPSMON_C"
+ config_get val "$cfg" noparentmsg
+ [ -n "$val" ] && echo "NOTIFYMSG NOPARENT \"$val\"" >> "$UPSMON_C"
+
+ notifylist() {
+ local value="$1"
+ append optval "$value" "+"
+ }
+
+ setnotify() {
+ local cfg="$1"
+ local optname="$2"
+ local optval
+ config_list_foreach "$cfg" "$optname" notifylist
+ if [ -z "$optval" ]; then
+ # If no list fallback to trying option, fallback to default
+ config_get optval "$cfg" "$optname" "$default"
+ if [ -n "$optval" ]; then
+ echo "$optval"
+ else
+ # No default, so do the NUT default
+ echo "SYSLOG"
+ fi
+ else
+ echo "$optval"
+ fi
+ }
+
+ local default optval
+ val=""
+ config_list_foreach "$cfg" defaultnotify notifylist
+ default="$optval"
+ {
+ echo "NOTIFYFLAG ONLINE $(setnotify "$cfg" onlinenotify)" ; \
+ echo "NOTIFYFLAG ONBATT $(setnotify "$cfg" onbattnotify)" ; \
+ echo "NOTIFYFLAG LOWBATT $(setnotify "$cfg" lowbatnotify)" ; \
+ echo "NOTIFYFLAG FSD $(setnotify "$cfg" fsdnotify)" ; \
+ echo "NOTIFYFLAG COMMOK $(setnotify "$cfg" commoknotify)" ; \
+ echo "NOTIFYFLAG COMMBAD $(setnotify "$cfg" commbadnotify)" ; \
+ echo "NOTIFYFLAG SHUTDOWN $(setnotify "$cfg" shutdownnotify)" ; \
+ echo "NOTIFYFLAG REPLBATT $(setnotify "$cfg" repolbattnotify)" ; \
+ echo "NOTIFYFLAG NOCOMM $(setnotify "$cfg" nocommnotify)" ; \
+ echo "NOTIFYFLAG NOPARENT $(setnotify "$cfg" noparentnotify)" ; \
+ } >> "$UPSMON_C"
+
+ config_get val "$cfg" rbwarntime 43200
+ echo "RBWARNTIME $val" >> "$UPSMON_C"
+
+ config_get val "$cfg" nocommwarntime 300
+ echo "NOCOMMWARNTIME $val" >> "$UPSMON_C"
+
+ config_get val "$cfg" finaldelay 5
+ echo "FINALDELAY $val" >> "$UPSMON_C"
+
+ config_get val "$cfg" certpath
+ if [ -n "$val" ]; then echo "CERTPATH $val" >> "$UPSMON_C"; fi
+
+ config_get_bool val "$cfg" certverify 0
+ if [ -n "$val" ]; then echo "CERTVERIFY $val" >> "$UPSMON_C"; fi
+
+ config_get_bool val "$cfg" forcessl 0
+ if [ -n "$val" ]; then echo "FORCESSL $val" >> "$UPSMON_C"; fi
+
+ havemon=1
+}
+
+nut_upsmon_add() {
+ local cfg="$1"
+ local type="$2"
+ local upsname
+ local hostname
+ local port
+ local powervalue
+ local username
+ local password
+ local system
+
+ config_get upsname "$cfg" upsname
+ config_get hostname "$cfg" hostname localhost
+ config_get port "$cfg" port
+ config_get powervalue "$cfg" powervalue 1
+ config_get username "$cfg" username
+ config_get password "$cfg" password
+ system="$upsname@$hostname"
+ if [ -n "$port" ]; then
+ system="$system:$port";
+ fi
+ echo "MONITOR $system $powervalue $username $password $type" >> "$UPSMON_C"
+
+ havems=1
+}
+
+build_config() {
+ mkdir -m 0750 -p "$(dirname "$UPSMON_C")"
+
+ config_load nut_monitor
+ config_foreach nut_upsmon_conf upsmon
+ config_foreach nut_upsmon_add master master
+ config_foreach nut_upsmon_add slave slave
+
+ [ ! -s /var/etc/nut/nut.conf ] && {
+ echo "MODE=netclient" >>/var/etc/nut/nut.conf
+ chmod 640 /var/etc/nut/nut.conf
+ chgrp "$(id -gn "${runas:-nutmon}")" /var/etc/nut/nut.conf
+ }
+
+ [ -s "$UPSMON_C" ] && chmod 640 "$UPSMON_C"
+ [ -s "$UPSMON_C" ] && chgrp "$(id -gn "${runas:-nutmon}")" "$UPSMON_C"
+}
+
+interface_triggers() {
+ local action="$1"
+ local triggerlist trigger
+
+ config_get triggerlist "upsmon" triggerlist
+
+ . "${IPKG_INSTROOT}"/lib/functions/network.sh
+
+ if [ -n "$triggerlist" ]; then
+ for trigger in $triggerlist; do
+ if [ "$action" = "add_trigger" ]; then
+ procd_add_interface_trigger "interface.*" "$trigger" /etc/init.d/nut-monitor restart
+ else
+ network_is_up "$trigger" && return 0
+ fi
+ done
+ else
+ if [ "$action" = "add_trigger" ]; then
+ procd_add_raw_trigger "interface.*.up" 2000 /etc/init.d/nut-monitor restart
+ else
+ ubus call network.device status | grep -q '"up": true' && return 0
+ fi
+ fi
+ [ "$action" = "add_trigger" ] || return 1
+}
+
+start_service() {
+ local runas=nutmon
+ local havemon havems
+ build_config
+
+ [ "$havemon" != 1 ] && return 1
+ [ "$havems" != 1 ] && return 1
+ interface_triggers "check_interface_up" || return 0
+
+ procd_open_instance "upsmon"
+ procd_set_param respawn 10 20 6
+ procd_set_param stderr 1
+ procd_set_param stdout 0
+ procd_set_param command /usr/sbin/upsmon -D
+ procd_close_instance
+
+ return 0
+}
+
+reload_service() {
+ if pgrep upsmon >/dev/null 2>/dev/null; then
+ local runas=nutmon
+ build_config
+ /usr/sbin/upsmon -c reload
+ else
+ restart
+ fi
+}
+
+stop_service() {
+ upsmon -c stop
+}
+
+service_triggers() {
+ config_load nut_monitor
+ interface_triggers "add_trigger"
+ procd_add_reload_trigger "nut_monitor"
+}