| #!/bin/sh /etc/rc.common |
| |
| START=82 |
| STOP=28 |
| USE_PROCD=1 |
| UPSMON_C=/var/etc/nut/upsmon.conf |
| |
| nut_upsmon_conf() { |
| local cfg="$1" |
| local RUNAS val optval |
| |
| echo "# Config file automatically generated from UCI config" > "$UPSMON_C" |
| |
| config_get RUNAS "$cfg" runas "nutmon" |
| [ -n "$RUNAS" ] && echo "RUN_AS_USER $RUNAS" >> "$UPSMON_C" |
| runas="$RUNAS" |
| |
| config_get val "$cfg" minsupplies 1 |
| echo "MINSUPPLIES $val" >> "$UPSMON_C" |
| |
| config_get val "$cfg" shutdowncmd "/usr/sbin/nutshutdown" |
| echo "SHUTDOWNCMD \"$val\"" >> "$UPSMON_C" |
| |
| config_get val "$cfg" notifycmd |
| [ -n "$val" ] && echo "NOTIFYCMD \"$val\"" >> "$UPSMON_C" |
| |
| config_get val "$cfg" pollfreq 5 |
| echo "POLLFREQ $val" >> "$UPSMON_C" |
| |
| config_get val "$cfg" pollfreqalert 5 |
| echo "POLLFREQALERT $val" >> "$UPSMON_C" |
| |
| config_get val "$cfg" hostsync 15 |
| echo "HOSTSYNC $val" >> "$UPSMON_C" |
| |
| config_get val "$cfg" deadtime 15 |
| echo "DEADTIME $val" >> "$UPSMON_C" |
| |
| echo "POWERDOWNFLAG /var/run/killpower" >> "$UPSMON_C" |
| |
| config_get val "$cfg" onlinemsg |
| [ -n "$val" ] && echo "NOTIFYMSG ONLINE \"$val\"" >> "$UPSMON_C" |
| config_get val "$cfg" onbattmsg |
| [ -n "$val" ] && echo "NOTIFYMSG ONBATT \"$val\"" >> "$UPSMON_C" |
| config_get val "$cfg" lowbattmsg |
| [ -n "$val" ] && echo "NOTIFYMSG LOWBATT \"$val\"" >> "$UPSMON_C" |
| config_get val "$cfg" fsdmsg |
| [ -n "$val" ] && echo "NOTIFYMSG FSD \"$val\"" >> "$UPSMON_C" |
| config_get val "$cfg" commokmsg |
| [ -n "$val" ] && echo "NOTIFYMSG COMMOK \"$val\"" >> "$UPSMON_C" |
| config_get val "$cfg" commbadmsg |
| [ -n "$val" ] && echo "NOTIFYMSG COMMBAD \"$val\"" >> "$UPSMON_C" |
| config_get val "$cfg" shutdownmsg |
| [ -n "$val" ] && echo "NOTIFYMSG SHUTDOWN \"$val\"" >> "$UPSMON_C" |
| config_get val "$cfg" replbattmsg |
| [ -n "$val" ] && echo "NOTIFYMSG REPLBATT \"$val\"" >> "$UPSMON_C" |
| config_get val "$cfg" nocommmsg |
| [ -n "$val" ] && echo "NOTIFYMSG NOCOMM \"$val\"" >> "$UPSMON_C" |
| config_get val "$cfg" noparentmsg |
| [ -n "$val" ] && echo "NOTIFYMSG NOPARENT \"$val\"" >> "$UPSMON_C" |
| |
| notifylist() { |
| local value="$1" |
| append optval "$value" "+" |
| } |
| |
| setnotify() { |
| local cfg="$1" |
| local optname="$2" |
| local optval |
| config_list_foreach "$cfg" "$optname" notifylist |
| if [ -z "$optval" ]; then |
| # If no list fallback to trying option, fallback to default |
| config_get optval "$cfg" "$optname" "$default" |
| if [ -n "$optval" ]; then |
| echo "$optval" |
| else |
| # No default, so do the NUT default |
| echo "SYSLOG" |
| fi |
| else |
| echo "$optval" |
| fi |
| } |
| |
| local default optval |
| val="" |
| config_list_foreach "$cfg" defaultnotify notifylist |
| default="$optval" |
| { |
| echo "NOTIFYFLAG ONLINE $(setnotify "$cfg" onlinenotify)" ; \ |
| echo "NOTIFYFLAG ONBATT $(setnotify "$cfg" onbattnotify)" ; \ |
| echo "NOTIFYFLAG LOWBATT $(setnotify "$cfg" lowbatnotify)" ; \ |
| echo "NOTIFYFLAG FSD $(setnotify "$cfg" fsdnotify)" ; \ |
| echo "NOTIFYFLAG COMMOK $(setnotify "$cfg" commoknotify)" ; \ |
| echo "NOTIFYFLAG COMMBAD $(setnotify "$cfg" commbadnotify)" ; \ |
| echo "NOTIFYFLAG SHUTDOWN $(setnotify "$cfg" shutdownnotify)" ; \ |
| echo "NOTIFYFLAG REPLBATT $(setnotify "$cfg" repolbattnotify)" ; \ |
| echo "NOTIFYFLAG NOCOMM $(setnotify "$cfg" nocommnotify)" ; \ |
| echo "NOTIFYFLAG NOPARENT $(setnotify "$cfg" noparentnotify)" ; \ |
| } >> "$UPSMON_C" |
| |
| config_get val "$cfg" rbwarntime 43200 |
| echo "RBWARNTIME $val" >> "$UPSMON_C" |
| |
| config_get val "$cfg" nocommwarntime 300 |
| echo "NOCOMMWARNTIME $val" >> "$UPSMON_C" |
| |
| config_get val "$cfg" finaldelay 5 |
| echo "FINALDELAY $val" >> "$UPSMON_C" |
| |
| config_get val "$cfg" certpath |
| if [ -n "$val" ]; then echo "CERTPATH $val" >> "$UPSMON_C"; fi |
| |
| config_get_bool val "$cfg" certverify 0 |
| if [ -n "$val" ]; then echo "CERTVERIFY $val" >> "$UPSMON_C"; fi |
| |
| config_get_bool val "$cfg" forcessl 0 |
| if [ -n "$val" ]; then echo "FORCESSL $val" >> "$UPSMON_C"; fi |
| |
| havemon=1 |
| } |
| |
| nut_upsmon_add() { |
| local cfg="$1" |
| local type="$2" |
| local upsname |
| local hostname |
| local port |
| local powervalue |
| local username |
| local password |
| local system |
| |
| config_get upsname "$cfg" upsname |
| config_get hostname "$cfg" hostname localhost |
| config_get port "$cfg" port |
| config_get powervalue "$cfg" powervalue 1 |
| config_get username "$cfg" username |
| config_get password "$cfg" password |
| system="$upsname@$hostname" |
| if [ -n "$port" ]; then |
| system="$system:$port"; |
| fi |
| echo "MONITOR $system $powervalue $username $password $type" >> "$UPSMON_C" |
| |
| havems=1 |
| } |
| |
| build_config() { |
| mkdir -m 0750 -p "$(dirname "$UPSMON_C")" |
| |
| config_load nut_monitor |
| config_foreach nut_upsmon_conf upsmon |
| config_foreach nut_upsmon_add master master |
| config_foreach nut_upsmon_add slave slave |
| |
| [ ! -s /var/etc/nut/nut.conf ] && { |
| echo "MODE=netclient" >>/var/etc/nut/nut.conf |
| chmod 640 /var/etc/nut/nut.conf |
| chgrp "$(id -gn "${runas:-nutmon}")" /var/etc/nut/nut.conf |
| } |
| |
| [ -s "$UPSMON_C" ] && chmod 640 "$UPSMON_C" |
| [ -s "$UPSMON_C" ] && chgrp "$(id -gn "${runas:-nutmon}")" "$UPSMON_C" |
| } |
| |
| interface_triggers() { |
| local action="$1" |
| local triggerlist trigger |
| |
| config_get triggerlist "upsmon" triggerlist |
| |
| . "${IPKG_INSTROOT}"/lib/functions/network.sh |
| |
| if [ -n "$triggerlist" ]; then |
| for trigger in $triggerlist; do |
| if [ "$action" = "add_trigger" ]; then |
| procd_add_interface_trigger "interface.*" "$trigger" /etc/init.d/nut-monitor restart |
| else |
| network_is_up "$trigger" && return 0 |
| fi |
| done |
| else |
| if [ "$action" = "add_trigger" ]; then |
| procd_add_raw_trigger "interface.*.up" 2000 /etc/init.d/nut-monitor restart |
| else |
| ubus call network.device status | grep -q '"up": true' && return 0 |
| fi |
| fi |
| [ "$action" = "add_trigger" ] || return 1 |
| } |
| |
| start_service() { |
| local runas=nutmon |
| local havemon havems |
| build_config |
| |
| [ "$havemon" != 1 ] && return 1 |
| [ "$havems" != 1 ] && return 1 |
| interface_triggers "check_interface_up" || return 0 |
| |
| procd_open_instance "upsmon" |
| procd_set_param respawn 10 20 6 |
| procd_set_param stderr 1 |
| procd_set_param stdout 0 |
| procd_set_param command /usr/sbin/upsmon -D |
| procd_close_instance |
| |
| return 0 |
| } |
| |
| reload_service() { |
| if pgrep upsmon >/dev/null 2>/dev/null; then |
| local runas=nutmon |
| build_config |
| /usr/sbin/upsmon -c reload |
| else |
| restart |
| fi |
| } |
| |
| stop_service() { |
| upsmon -c stop |
| } |
| |
| service_triggers() { |
| config_load nut_monitor |
| interface_triggers "add_trigger" |
| procd_add_reload_trigger "nut_monitor" |
| } |