b.liu | e958203 | 2025-04-17 19:18:16 +0800 | [diff] [blame] | 1 | #!/bin/sh /etc/rc.common |
| 2 | |
| 3 | START=82 |
| 4 | STOP=28 |
| 5 | USE_PROCD=1 |
| 6 | UPSMON_C=/var/etc/nut/upsmon.conf |
| 7 | |
| 8 | nut_upsmon_conf() { |
| 9 | local cfg="$1" |
| 10 | local RUNAS val optval |
| 11 | |
| 12 | echo "# Config file automatically generated from UCI config" > "$UPSMON_C" |
| 13 | |
| 14 | config_get RUNAS "$cfg" runas "nutmon" |
| 15 | [ -n "$RUNAS" ] && echo "RUN_AS_USER $RUNAS" >> "$UPSMON_C" |
| 16 | runas="$RUNAS" |
| 17 | |
| 18 | config_get val "$cfg" minsupplies 1 |
| 19 | echo "MINSUPPLIES $val" >> "$UPSMON_C" |
| 20 | |
| 21 | config_get val "$cfg" shutdowncmd "/usr/sbin/nutshutdown" |
| 22 | echo "SHUTDOWNCMD \"$val\"" >> "$UPSMON_C" |
| 23 | |
| 24 | config_get val "$cfg" notifycmd |
| 25 | [ -n "$val" ] && echo "NOTIFYCMD \"$val\"" >> "$UPSMON_C" |
| 26 | |
| 27 | config_get val "$cfg" pollfreq 5 |
| 28 | echo "POLLFREQ $val" >> "$UPSMON_C" |
| 29 | |
| 30 | config_get val "$cfg" pollfreqalert 5 |
| 31 | echo "POLLFREQALERT $val" >> "$UPSMON_C" |
| 32 | |
| 33 | config_get val "$cfg" hostsync 15 |
| 34 | echo "HOSTSYNC $val" >> "$UPSMON_C" |
| 35 | |
| 36 | config_get val "$cfg" deadtime 15 |
| 37 | echo "DEADTIME $val" >> "$UPSMON_C" |
| 38 | |
| 39 | echo "POWERDOWNFLAG /var/run/killpower" >> "$UPSMON_C" |
| 40 | |
| 41 | config_get val "$cfg" onlinemsg |
| 42 | [ -n "$val" ] && echo "NOTIFYMSG ONLINE \"$val\"" >> "$UPSMON_C" |
| 43 | config_get val "$cfg" onbattmsg |
| 44 | [ -n "$val" ] && echo "NOTIFYMSG ONBATT \"$val\"" >> "$UPSMON_C" |
| 45 | config_get val "$cfg" lowbattmsg |
| 46 | [ -n "$val" ] && echo "NOTIFYMSG LOWBATT \"$val\"" >> "$UPSMON_C" |
| 47 | config_get val "$cfg" fsdmsg |
| 48 | [ -n "$val" ] && echo "NOTIFYMSG FSD \"$val\"" >> "$UPSMON_C" |
| 49 | config_get val "$cfg" commokmsg |
| 50 | [ -n "$val" ] && echo "NOTIFYMSG COMMOK \"$val\"" >> "$UPSMON_C" |
| 51 | config_get val "$cfg" commbadmsg |
| 52 | [ -n "$val" ] && echo "NOTIFYMSG COMMBAD \"$val\"" >> "$UPSMON_C" |
| 53 | config_get val "$cfg" shutdownmsg |
| 54 | [ -n "$val" ] && echo "NOTIFYMSG SHUTDOWN \"$val\"" >> "$UPSMON_C" |
| 55 | config_get val "$cfg" replbattmsg |
| 56 | [ -n "$val" ] && echo "NOTIFYMSG REPLBATT \"$val\"" >> "$UPSMON_C" |
| 57 | config_get val "$cfg" nocommmsg |
| 58 | [ -n "$val" ] && echo "NOTIFYMSG NOCOMM \"$val\"" >> "$UPSMON_C" |
| 59 | config_get val "$cfg" noparentmsg |
| 60 | [ -n "$val" ] && echo "NOTIFYMSG NOPARENT \"$val\"" >> "$UPSMON_C" |
| 61 | |
| 62 | notifylist() { |
| 63 | local value="$1" |
| 64 | append optval "$value" "+" |
| 65 | } |
| 66 | |
| 67 | setnotify() { |
| 68 | local cfg="$1" |
| 69 | local optname="$2" |
| 70 | local optval |
| 71 | config_list_foreach "$cfg" "$optname" notifylist |
| 72 | if [ -z "$optval" ]; then |
| 73 | # If no list fallback to trying option, fallback to default |
| 74 | config_get optval "$cfg" "$optname" "$default" |
| 75 | if [ -n "$optval" ]; then |
| 76 | echo "$optval" |
| 77 | else |
| 78 | # No default, so do the NUT default |
| 79 | echo "SYSLOG" |
| 80 | fi |
| 81 | else |
| 82 | echo "$optval" |
| 83 | fi |
| 84 | } |
| 85 | |
| 86 | local default optval |
| 87 | val="" |
| 88 | config_list_foreach "$cfg" defaultnotify notifylist |
| 89 | default="$optval" |
| 90 | { |
| 91 | echo "NOTIFYFLAG ONLINE $(setnotify "$cfg" onlinenotify)" ; \ |
| 92 | echo "NOTIFYFLAG ONBATT $(setnotify "$cfg" onbattnotify)" ; \ |
| 93 | echo "NOTIFYFLAG LOWBATT $(setnotify "$cfg" lowbatnotify)" ; \ |
| 94 | echo "NOTIFYFLAG FSD $(setnotify "$cfg" fsdnotify)" ; \ |
| 95 | echo "NOTIFYFLAG COMMOK $(setnotify "$cfg" commoknotify)" ; \ |
| 96 | echo "NOTIFYFLAG COMMBAD $(setnotify "$cfg" commbadnotify)" ; \ |
| 97 | echo "NOTIFYFLAG SHUTDOWN $(setnotify "$cfg" shutdownnotify)" ; \ |
| 98 | echo "NOTIFYFLAG REPLBATT $(setnotify "$cfg" repolbattnotify)" ; \ |
| 99 | echo "NOTIFYFLAG NOCOMM $(setnotify "$cfg" nocommnotify)" ; \ |
| 100 | echo "NOTIFYFLAG NOPARENT $(setnotify "$cfg" noparentnotify)" ; \ |
| 101 | } >> "$UPSMON_C" |
| 102 | |
| 103 | config_get val "$cfg" rbwarntime 43200 |
| 104 | echo "RBWARNTIME $val" >> "$UPSMON_C" |
| 105 | |
| 106 | config_get val "$cfg" nocommwarntime 300 |
| 107 | echo "NOCOMMWARNTIME $val" >> "$UPSMON_C" |
| 108 | |
| 109 | config_get val "$cfg" finaldelay 5 |
| 110 | echo "FINALDELAY $val" >> "$UPSMON_C" |
| 111 | |
| 112 | config_get val "$cfg" certpath |
| 113 | if [ -n "$val" ]; then echo "CERTPATH $val" >> "$UPSMON_C"; fi |
| 114 | |
| 115 | config_get_bool val "$cfg" certverify 0 |
| 116 | if [ -n "$val" ]; then echo "CERTVERIFY $val" >> "$UPSMON_C"; fi |
| 117 | |
| 118 | config_get_bool val "$cfg" forcessl 0 |
| 119 | if [ -n "$val" ]; then echo "FORCESSL $val" >> "$UPSMON_C"; fi |
| 120 | |
| 121 | havemon=1 |
| 122 | } |
| 123 | |
| 124 | nut_upsmon_add() { |
| 125 | local cfg="$1" |
| 126 | local type="$2" |
| 127 | local upsname |
| 128 | local hostname |
| 129 | local port |
| 130 | local powervalue |
| 131 | local username |
| 132 | local password |
| 133 | local system |
| 134 | |
| 135 | config_get upsname "$cfg" upsname |
| 136 | config_get hostname "$cfg" hostname localhost |
| 137 | config_get port "$cfg" port |
| 138 | config_get powervalue "$cfg" powervalue 1 |
| 139 | config_get username "$cfg" username |
| 140 | config_get password "$cfg" password |
| 141 | system="$upsname@$hostname" |
| 142 | if [ -n "$port" ]; then |
| 143 | system="$system:$port"; |
| 144 | fi |
| 145 | echo "MONITOR $system $powervalue $username $password $type" >> "$UPSMON_C" |
| 146 | |
| 147 | havems=1 |
| 148 | } |
| 149 | |
| 150 | build_config() { |
| 151 | mkdir -m 0750 -p "$(dirname "$UPSMON_C")" |
| 152 | |
| 153 | config_load nut_monitor |
| 154 | config_foreach nut_upsmon_conf upsmon |
| 155 | config_foreach nut_upsmon_add master master |
| 156 | config_foreach nut_upsmon_add slave slave |
| 157 | |
| 158 | [ ! -s /var/etc/nut/nut.conf ] && { |
| 159 | echo "MODE=netclient" >>/var/etc/nut/nut.conf |
| 160 | chmod 640 /var/etc/nut/nut.conf |
| 161 | chgrp "$(id -gn "${runas:-nutmon}")" /var/etc/nut/nut.conf |
| 162 | } |
| 163 | |
| 164 | [ -s "$UPSMON_C" ] && chmod 640 "$UPSMON_C" |
| 165 | [ -s "$UPSMON_C" ] && chgrp "$(id -gn "${runas:-nutmon}")" "$UPSMON_C" |
| 166 | } |
| 167 | |
| 168 | interface_triggers() { |
| 169 | local action="$1" |
| 170 | local triggerlist trigger |
| 171 | |
| 172 | config_get triggerlist "upsmon" triggerlist |
| 173 | |
| 174 | . "${IPKG_INSTROOT}"/lib/functions/network.sh |
| 175 | |
| 176 | if [ -n "$triggerlist" ]; then |
| 177 | for trigger in $triggerlist; do |
| 178 | if [ "$action" = "add_trigger" ]; then |
| 179 | procd_add_interface_trigger "interface.*" "$trigger" /etc/init.d/nut-monitor restart |
| 180 | else |
| 181 | network_is_up "$trigger" && return 0 |
| 182 | fi |
| 183 | done |
| 184 | else |
| 185 | if [ "$action" = "add_trigger" ]; then |
| 186 | procd_add_raw_trigger "interface.*.up" 2000 /etc/init.d/nut-monitor restart |
| 187 | else |
| 188 | ubus call network.device status | grep -q '"up": true' && return 0 |
| 189 | fi |
| 190 | fi |
| 191 | [ "$action" = "add_trigger" ] || return 1 |
| 192 | } |
| 193 | |
| 194 | start_service() { |
| 195 | local runas=nutmon |
| 196 | local havemon havems |
| 197 | build_config |
| 198 | |
| 199 | [ "$havemon" != 1 ] && return 1 |
| 200 | [ "$havems" != 1 ] && return 1 |
| 201 | interface_triggers "check_interface_up" || return 0 |
| 202 | |
| 203 | procd_open_instance "upsmon" |
| 204 | procd_set_param respawn 10 20 6 |
| 205 | procd_set_param stderr 1 |
| 206 | procd_set_param stdout 0 |
| 207 | procd_set_param command /usr/sbin/upsmon -D |
| 208 | procd_close_instance |
| 209 | |
| 210 | return 0 |
| 211 | } |
| 212 | |
| 213 | reload_service() { |
| 214 | if pgrep upsmon >/dev/null 2>/dev/null; then |
| 215 | local runas=nutmon |
| 216 | build_config |
| 217 | /usr/sbin/upsmon -c reload |
| 218 | else |
| 219 | restart |
| 220 | fi |
| 221 | } |
| 222 | |
| 223 | stop_service() { |
| 224 | upsmon -c stop |
| 225 | } |
| 226 | |
| 227 | service_triggers() { |
| 228 | config_load nut_monitor |
| 229 | interface_triggers "add_trigger" |
| 230 | procd_add_reload_trigger "nut_monitor" |
| 231 | } |