b.liue9582032025-04-17 19:18:16 +08001#!/bin/sh /etc/rc.common
2
3START=82
4STOP=28
5USE_PROCD=1
6UPSMON_C=/var/etc/nut/upsmon.conf
7
8nut_upsmon_conf() {
9 local cfg="$1"
10 local RUNAS val optval
11
12 echo "# Config file automatically generated from UCI config" > "$UPSMON_C"
13
14 config_get RUNAS "$cfg" runas "nutmon"
15 [ -n "$RUNAS" ] && echo "RUN_AS_USER $RUNAS" >> "$UPSMON_C"
16 runas="$RUNAS"
17
18 config_get val "$cfg" minsupplies 1
19 echo "MINSUPPLIES $val" >> "$UPSMON_C"
20
21 config_get val "$cfg" shutdowncmd "/usr/sbin/nutshutdown"
22 echo "SHUTDOWNCMD \"$val\"" >> "$UPSMON_C"
23
24 config_get val "$cfg" notifycmd
25 [ -n "$val" ] && echo "NOTIFYCMD \"$val\"" >> "$UPSMON_C"
26
27 config_get val "$cfg" pollfreq 5
28 echo "POLLFREQ $val" >> "$UPSMON_C"
29
30 config_get val "$cfg" pollfreqalert 5
31 echo "POLLFREQALERT $val" >> "$UPSMON_C"
32
33 config_get val "$cfg" hostsync 15
34 echo "HOSTSYNC $val" >> "$UPSMON_C"
35
36 config_get val "$cfg" deadtime 15
37 echo "DEADTIME $val" >> "$UPSMON_C"
38
39 echo "POWERDOWNFLAG /var/run/killpower" >> "$UPSMON_C"
40
41 config_get val "$cfg" onlinemsg
42 [ -n "$val" ] && echo "NOTIFYMSG ONLINE \"$val\"" >> "$UPSMON_C"
43 config_get val "$cfg" onbattmsg
44 [ -n "$val" ] && echo "NOTIFYMSG ONBATT \"$val\"" >> "$UPSMON_C"
45 config_get val "$cfg" lowbattmsg
46 [ -n "$val" ] && echo "NOTIFYMSG LOWBATT \"$val\"" >> "$UPSMON_C"
47 config_get val "$cfg" fsdmsg
48 [ -n "$val" ] && echo "NOTIFYMSG FSD \"$val\"" >> "$UPSMON_C"
49 config_get val "$cfg" commokmsg
50 [ -n "$val" ] && echo "NOTIFYMSG COMMOK \"$val\"" >> "$UPSMON_C"
51 config_get val "$cfg" commbadmsg
52 [ -n "$val" ] && echo "NOTIFYMSG COMMBAD \"$val\"" >> "$UPSMON_C"
53 config_get val "$cfg" shutdownmsg
54 [ -n "$val" ] && echo "NOTIFYMSG SHUTDOWN \"$val\"" >> "$UPSMON_C"
55 config_get val "$cfg" replbattmsg
56 [ -n "$val" ] && echo "NOTIFYMSG REPLBATT \"$val\"" >> "$UPSMON_C"
57 config_get val "$cfg" nocommmsg
58 [ -n "$val" ] && echo "NOTIFYMSG NOCOMM \"$val\"" >> "$UPSMON_C"
59 config_get val "$cfg" noparentmsg
60 [ -n "$val" ] && echo "NOTIFYMSG NOPARENT \"$val\"" >> "$UPSMON_C"
61
62 notifylist() {
63 local value="$1"
64 append optval "$value" "+"
65 }
66
67 setnotify() {
68 local cfg="$1"
69 local optname="$2"
70 local optval
71 config_list_foreach "$cfg" "$optname" notifylist
72 if [ -z "$optval" ]; then
73 # If no list fallback to trying option, fallback to default
74 config_get optval "$cfg" "$optname" "$default"
75 if [ -n "$optval" ]; then
76 echo "$optval"
77 else
78 # No default, so do the NUT default
79 echo "SYSLOG"
80 fi
81 else
82 echo "$optval"
83 fi
84 }
85
86 local default optval
87 val=""
88 config_list_foreach "$cfg" defaultnotify notifylist
89 default="$optval"
90 {
91 echo "NOTIFYFLAG ONLINE $(setnotify "$cfg" onlinenotify)" ; \
92 echo "NOTIFYFLAG ONBATT $(setnotify "$cfg" onbattnotify)" ; \
93 echo "NOTIFYFLAG LOWBATT $(setnotify "$cfg" lowbatnotify)" ; \
94 echo "NOTIFYFLAG FSD $(setnotify "$cfg" fsdnotify)" ; \
95 echo "NOTIFYFLAG COMMOK $(setnotify "$cfg" commoknotify)" ; \
96 echo "NOTIFYFLAG COMMBAD $(setnotify "$cfg" commbadnotify)" ; \
97 echo "NOTIFYFLAG SHUTDOWN $(setnotify "$cfg" shutdownnotify)" ; \
98 echo "NOTIFYFLAG REPLBATT $(setnotify "$cfg" repolbattnotify)" ; \
99 echo "NOTIFYFLAG NOCOMM $(setnotify "$cfg" nocommnotify)" ; \
100 echo "NOTIFYFLAG NOPARENT $(setnotify "$cfg" noparentnotify)" ; \
101 } >> "$UPSMON_C"
102
103 config_get val "$cfg" rbwarntime 43200
104 echo "RBWARNTIME $val" >> "$UPSMON_C"
105
106 config_get val "$cfg" nocommwarntime 300
107 echo "NOCOMMWARNTIME $val" >> "$UPSMON_C"
108
109 config_get val "$cfg" finaldelay 5
110 echo "FINALDELAY $val" >> "$UPSMON_C"
111
112 config_get val "$cfg" certpath
113 if [ -n "$val" ]; then echo "CERTPATH $val" >> "$UPSMON_C"; fi
114
115 config_get_bool val "$cfg" certverify 0
116 if [ -n "$val" ]; then echo "CERTVERIFY $val" >> "$UPSMON_C"; fi
117
118 config_get_bool val "$cfg" forcessl 0
119 if [ -n "$val" ]; then echo "FORCESSL $val" >> "$UPSMON_C"; fi
120
121 havemon=1
122}
123
124nut_upsmon_add() {
125 local cfg="$1"
126 local type="$2"
127 local upsname
128 local hostname
129 local port
130 local powervalue
131 local username
132 local password
133 local system
134
135 config_get upsname "$cfg" upsname
136 config_get hostname "$cfg" hostname localhost
137 config_get port "$cfg" port
138 config_get powervalue "$cfg" powervalue 1
139 config_get username "$cfg" username
140 config_get password "$cfg" password
141 system="$upsname@$hostname"
142 if [ -n "$port" ]; then
143 system="$system:$port";
144 fi
145 echo "MONITOR $system $powervalue $username $password $type" >> "$UPSMON_C"
146
147 havems=1
148}
149
150build_config() {
151 mkdir -m 0750 -p "$(dirname "$UPSMON_C")"
152
153 config_load nut_monitor
154 config_foreach nut_upsmon_conf upsmon
155 config_foreach nut_upsmon_add master master
156 config_foreach nut_upsmon_add slave slave
157
158 [ ! -s /var/etc/nut/nut.conf ] && {
159 echo "MODE=netclient" >>/var/etc/nut/nut.conf
160 chmod 640 /var/etc/nut/nut.conf
161 chgrp "$(id -gn "${runas:-nutmon}")" /var/etc/nut/nut.conf
162 }
163
164 [ -s "$UPSMON_C" ] && chmod 640 "$UPSMON_C"
165 [ -s "$UPSMON_C" ] && chgrp "$(id -gn "${runas:-nutmon}")" "$UPSMON_C"
166}
167
168interface_triggers() {
169 local action="$1"
170 local triggerlist trigger
171
172 config_get triggerlist "upsmon" triggerlist
173
174 . "${IPKG_INSTROOT}"/lib/functions/network.sh
175
176 if [ -n "$triggerlist" ]; then
177 for trigger in $triggerlist; do
178 if [ "$action" = "add_trigger" ]; then
179 procd_add_interface_trigger "interface.*" "$trigger" /etc/init.d/nut-monitor restart
180 else
181 network_is_up "$trigger" && return 0
182 fi
183 done
184 else
185 if [ "$action" = "add_trigger" ]; then
186 procd_add_raw_trigger "interface.*.up" 2000 /etc/init.d/nut-monitor restart
187 else
188 ubus call network.device status | grep -q '"up": true' && return 0
189 fi
190 fi
191 [ "$action" = "add_trigger" ] || return 1
192}
193
194start_service() {
195 local runas=nutmon
196 local havemon havems
197 build_config
198
199 [ "$havemon" != 1 ] && return 1
200 [ "$havems" != 1 ] && return 1
201 interface_triggers "check_interface_up" || return 0
202
203 procd_open_instance "upsmon"
204 procd_set_param respawn 10 20 6
205 procd_set_param stderr 1
206 procd_set_param stdout 0
207 procd_set_param command /usr/sbin/upsmon -D
208 procd_close_instance
209
210 return 0
211}
212
213reload_service() {
214 if pgrep upsmon >/dev/null 2>/dev/null; then
215 local runas=nutmon
216 build_config
217 /usr/sbin/upsmon -c reload
218 else
219 restart
220 fi
221}
222
223stop_service() {
224 upsmon -c stop
225}
226
227service_triggers() {
228 config_load nut_monitor
229 interface_triggers "add_trigger"
230 procd_add_reload_trigger "nut_monitor"