|  | What:		/sys/class/leds/<led>/device_name | 
|  | Date:		Dec 2017 | 
|  | KernelVersion:	4.16 | 
|  | Contact:	linux-leds@vger.kernel.org | 
|  | Description: | 
|  | Specifies the network device name to monitor. | 
|  |  | 
|  | What:		/sys/class/leds/<led>/interval | 
|  | Date:		Dec 2017 | 
|  | KernelVersion:	4.16 | 
|  | Contact:	linux-leds@vger.kernel.org | 
|  | Description: | 
|  | Specifies the duration of the LED blink in milliseconds. | 
|  | Defaults to 50 ms. | 
|  |  | 
|  | What:		/sys/class/leds/<led>/link | 
|  | Date:		Dec 2017 | 
|  | KernelVersion:	4.16 | 
|  | Contact:	linux-leds@vger.kernel.org | 
|  | Description: | 
|  | Signal the link state of the named network device. | 
|  | If set to 0 (default), the LED's normal state is off. | 
|  | If set to 1, the LED's normal state reflects the link state | 
|  | of the named network device. | 
|  | Setting this value also immediately changes the LED state. | 
|  |  | 
|  | What:		/sys/class/leds/<led>/tx | 
|  | Date:		Dec 2017 | 
|  | KernelVersion:	4.16 | 
|  | Contact:	linux-leds@vger.kernel.org | 
|  | Description: | 
|  | Signal transmission of data on the named network device. | 
|  | If set to 0 (default), the LED will not blink on transmission. | 
|  | If set to 1, the LED will blink for the milliseconds specified | 
|  | in interval to signal transmission. | 
|  |  | 
|  | What:		/sys/class/leds/<led>/rx | 
|  | Date:		Dec 2017 | 
|  | KernelVersion:	4.16 | 
|  | Contact:	linux-leds@vger.kernel.org | 
|  | Description: | 
|  | Signal reception of data on the named network device. | 
|  | If set to 0 (default), the LED will not blink on reception. | 
|  | If set to 1, the LED will blink for the milliseconds specified | 
|  | in interval to signal reception. |