| xj | b04a402 | 2021-11-25 15:01:52 +0800 | [diff] [blame] | 1 | /* | 
 | 2 |  * Copyright (c) 2006, 2018 Oracle and/or its affiliates. All rights reserved. | 
 | 3 |  * | 
 | 4 |  * This software is available to you under a choice of one of two | 
 | 5 |  * licenses.  You may choose to be licensed under the terms of the GNU | 
 | 6 |  * General Public License (GPL) Version 2, available from the file | 
 | 7 |  * COPYING in the main directory of this source tree, or the | 
 | 8 |  * OpenIB.org BSD license below: | 
 | 9 |  * | 
 | 10 |  *     Redistribution and use in source and binary forms, with or | 
 | 11 |  *     without modification, are permitted provided that the following | 
 | 12 |  *     conditions are met: | 
 | 13 |  * | 
 | 14 |  *      - Redistributions of source code must retain the above | 
 | 15 |  *        copyright notice, this list of conditions and the following | 
 | 16 |  *        disclaimer. | 
 | 17 |  * | 
 | 18 |  *      - Redistributions in binary form must reproduce the above | 
 | 19 |  *        copyright notice, this list of conditions and the following | 
 | 20 |  *        disclaimer in the documentation and/or other materials | 
 | 21 |  *        provided with the distribution. | 
 | 22 |  * | 
 | 23 |  * THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, | 
 | 24 |  * EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF | 
 | 25 |  * MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND | 
 | 26 |  * NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS | 
 | 27 |  * BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN | 
 | 28 |  * ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN | 
 | 29 |  * CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE | 
 | 30 |  * SOFTWARE. | 
 | 31 |  * | 
 | 32 |  */ | 
 | 33 | #include <linux/kernel.h> | 
 | 34 | #include <linux/in.h> | 
 | 35 | #include <linux/if.h> | 
 | 36 | #include <linux/netdevice.h> | 
 | 37 | #include <linux/inetdevice.h> | 
 | 38 | #include <linux/if_arp.h> | 
 | 39 | #include <linux/delay.h> | 
 | 40 | #include <linux/slab.h> | 
 | 41 | #include <linux/module.h> | 
 | 42 | #include <net/addrconf.h> | 
 | 43 |  | 
 | 44 | #include "rds_single_path.h" | 
 | 45 | #include "rds.h" | 
 | 46 | #include "ib.h" | 
 | 47 | #include "ib_mr.h" | 
 | 48 |  | 
 | 49 | static unsigned int rds_ib_mr_1m_pool_size = RDS_MR_1M_POOL_SIZE; | 
 | 50 | static unsigned int rds_ib_mr_8k_pool_size = RDS_MR_8K_POOL_SIZE; | 
 | 51 | unsigned int rds_ib_retry_count = RDS_IB_DEFAULT_RETRY_COUNT; | 
 | 52 | static atomic_t rds_ib_unloading; | 
 | 53 |  | 
 | 54 | module_param(rds_ib_mr_1m_pool_size, int, 0444); | 
 | 55 | MODULE_PARM_DESC(rds_ib_mr_1m_pool_size, " Max number of 1M mr per HCA"); | 
 | 56 | module_param(rds_ib_mr_8k_pool_size, int, 0444); | 
 | 57 | MODULE_PARM_DESC(rds_ib_mr_8k_pool_size, " Max number of 8K mr per HCA"); | 
 | 58 | module_param(rds_ib_retry_count, int, 0444); | 
 | 59 | MODULE_PARM_DESC(rds_ib_retry_count, " Number of hw retries before reporting an error"); | 
 | 60 |  | 
 | 61 | /* | 
 | 62 |  * we have a clumsy combination of RCU and a rwsem protecting this list | 
 | 63 |  * because it is used both in the get_mr fast path and while blocking in | 
 | 64 |  * the FMR flushing path. | 
 | 65 |  */ | 
 | 66 | DECLARE_RWSEM(rds_ib_devices_lock); | 
 | 67 | struct list_head rds_ib_devices; | 
 | 68 |  | 
 | 69 | /* NOTE: if also grabbing ibdev lock, grab this first */ | 
 | 70 | DEFINE_SPINLOCK(ib_nodev_conns_lock); | 
 | 71 | LIST_HEAD(ib_nodev_conns); | 
 | 72 |  | 
 | 73 | static void rds_ib_nodev_connect(void) | 
 | 74 | { | 
 | 75 | 	struct rds_ib_connection *ic; | 
 | 76 |  | 
 | 77 | 	spin_lock(&ib_nodev_conns_lock); | 
 | 78 | 	list_for_each_entry(ic, &ib_nodev_conns, ib_node) | 
 | 79 | 		rds_conn_connect_if_down(ic->conn); | 
 | 80 | 	spin_unlock(&ib_nodev_conns_lock); | 
 | 81 | } | 
 | 82 |  | 
 | 83 | static void rds_ib_dev_shutdown(struct rds_ib_device *rds_ibdev) | 
 | 84 | { | 
 | 85 | 	struct rds_ib_connection *ic; | 
 | 86 | 	unsigned long flags; | 
 | 87 |  | 
 | 88 | 	spin_lock_irqsave(&rds_ibdev->spinlock, flags); | 
 | 89 | 	list_for_each_entry(ic, &rds_ibdev->conn_list, ib_node) | 
 | 90 | 		rds_conn_drop(ic->conn); | 
 | 91 | 	spin_unlock_irqrestore(&rds_ibdev->spinlock, flags); | 
 | 92 | } | 
 | 93 |  | 
 | 94 | /* | 
 | 95 |  * rds_ib_destroy_mr_pool() blocks on a few things and mrs drop references | 
 | 96 |  * from interrupt context so we push freing off into a work struct in krdsd. | 
 | 97 |  */ | 
 | 98 | static void rds_ib_dev_free(struct work_struct *work) | 
 | 99 | { | 
 | 100 | 	struct rds_ib_ipaddr *i_ipaddr, *i_next; | 
 | 101 | 	struct rds_ib_device *rds_ibdev = container_of(work, | 
 | 102 | 					struct rds_ib_device, free_work); | 
 | 103 |  | 
 | 104 | 	if (rds_ibdev->mr_8k_pool) | 
 | 105 | 		rds_ib_destroy_mr_pool(rds_ibdev->mr_8k_pool); | 
 | 106 | 	if (rds_ibdev->mr_1m_pool) | 
 | 107 | 		rds_ib_destroy_mr_pool(rds_ibdev->mr_1m_pool); | 
 | 108 | 	if (rds_ibdev->pd) | 
 | 109 | 		ib_dealloc_pd(rds_ibdev->pd); | 
 | 110 |  | 
 | 111 | 	list_for_each_entry_safe(i_ipaddr, i_next, &rds_ibdev->ipaddr_list, list) { | 
 | 112 | 		list_del(&i_ipaddr->list); | 
 | 113 | 		kfree(i_ipaddr); | 
 | 114 | 	} | 
 | 115 |  | 
 | 116 | 	kfree(rds_ibdev->vector_load); | 
 | 117 |  | 
 | 118 | 	kfree(rds_ibdev); | 
 | 119 | } | 
 | 120 |  | 
 | 121 | void rds_ib_dev_put(struct rds_ib_device *rds_ibdev) | 
 | 122 | { | 
 | 123 | 	BUG_ON(refcount_read(&rds_ibdev->refcount) == 0); | 
 | 124 | 	if (refcount_dec_and_test(&rds_ibdev->refcount)) | 
 | 125 | 		queue_work(rds_wq, &rds_ibdev->free_work); | 
 | 126 | } | 
 | 127 |  | 
 | 128 | static void rds_ib_add_one(struct ib_device *device) | 
 | 129 | { | 
 | 130 | 	struct rds_ib_device *rds_ibdev; | 
 | 131 | 	bool has_fr, has_fmr; | 
 | 132 |  | 
 | 133 | 	/* Only handle IB (no iWARP) devices */ | 
 | 134 | 	if (device->node_type != RDMA_NODE_IB_CA) | 
 | 135 | 		return; | 
 | 136 |  | 
 | 137 | 	rds_ibdev = kzalloc_node(sizeof(struct rds_ib_device), GFP_KERNEL, | 
 | 138 | 				 ibdev_to_node(device)); | 
 | 139 | 	if (!rds_ibdev) | 
 | 140 | 		return; | 
 | 141 |  | 
 | 142 | 	spin_lock_init(&rds_ibdev->spinlock); | 
 | 143 | 	refcount_set(&rds_ibdev->refcount, 1); | 
 | 144 | 	INIT_WORK(&rds_ibdev->free_work, rds_ib_dev_free); | 
 | 145 |  | 
 | 146 | 	INIT_LIST_HEAD(&rds_ibdev->ipaddr_list); | 
 | 147 | 	INIT_LIST_HEAD(&rds_ibdev->conn_list); | 
 | 148 |  | 
 | 149 | 	rds_ibdev->max_wrs = device->attrs.max_qp_wr; | 
 | 150 | 	rds_ibdev->max_sge = min(device->attrs.max_send_sge, RDS_IB_MAX_SGE); | 
 | 151 |  | 
 | 152 | 	has_fr = (device->attrs.device_cap_flags & | 
 | 153 | 		  IB_DEVICE_MEM_MGT_EXTENSIONS); | 
 | 154 | 	has_fmr = (device->alloc_fmr && device->dealloc_fmr && | 
 | 155 | 		   device->map_phys_fmr && device->unmap_fmr); | 
 | 156 | 	rds_ibdev->use_fastreg = (has_fr && !has_fmr); | 
 | 157 |  | 
 | 158 | 	rds_ibdev->fmr_max_remaps = device->attrs.max_map_per_fmr?: 32; | 
 | 159 | 	rds_ibdev->max_1m_mrs = device->attrs.max_mr ? | 
 | 160 | 		min_t(unsigned int, (device->attrs.max_mr / 2), | 
 | 161 | 		      rds_ib_mr_1m_pool_size) : rds_ib_mr_1m_pool_size; | 
 | 162 |  | 
 | 163 | 	rds_ibdev->max_8k_mrs = device->attrs.max_mr ? | 
 | 164 | 		min_t(unsigned int, ((device->attrs.max_mr / 2) * RDS_MR_8K_SCALE), | 
 | 165 | 		      rds_ib_mr_8k_pool_size) : rds_ib_mr_8k_pool_size; | 
 | 166 |  | 
 | 167 | 	rds_ibdev->max_initiator_depth = device->attrs.max_qp_init_rd_atom; | 
 | 168 | 	rds_ibdev->max_responder_resources = device->attrs.max_qp_rd_atom; | 
 | 169 |  | 
 | 170 | 	rds_ibdev->vector_load = kcalloc(device->num_comp_vectors, | 
 | 171 | 					 sizeof(int), | 
 | 172 | 					 GFP_KERNEL); | 
 | 173 | 	if (!rds_ibdev->vector_load) { | 
 | 174 | 		pr_err("RDS/IB: %s failed to allocate vector memory\n", | 
 | 175 | 			__func__); | 
 | 176 | 		goto put_dev; | 
 | 177 | 	} | 
 | 178 |  | 
 | 179 | 	rds_ibdev->dev = device; | 
 | 180 | 	rds_ibdev->pd = ib_alloc_pd(device, 0); | 
 | 181 | 	if (IS_ERR(rds_ibdev->pd)) { | 
 | 182 | 		rds_ibdev->pd = NULL; | 
 | 183 | 		goto put_dev; | 
 | 184 | 	} | 
 | 185 |  | 
 | 186 | 	rds_ibdev->mr_1m_pool = | 
 | 187 | 		rds_ib_create_mr_pool(rds_ibdev, RDS_IB_MR_1M_POOL); | 
 | 188 | 	if (IS_ERR(rds_ibdev->mr_1m_pool)) { | 
 | 189 | 		rds_ibdev->mr_1m_pool = NULL; | 
 | 190 | 		goto put_dev; | 
 | 191 | 	} | 
 | 192 |  | 
 | 193 | 	rds_ibdev->mr_8k_pool = | 
 | 194 | 		rds_ib_create_mr_pool(rds_ibdev, RDS_IB_MR_8K_POOL); | 
 | 195 | 	if (IS_ERR(rds_ibdev->mr_8k_pool)) { | 
 | 196 | 		rds_ibdev->mr_8k_pool = NULL; | 
 | 197 | 		goto put_dev; | 
 | 198 | 	} | 
 | 199 |  | 
 | 200 | 	rdsdebug("RDS/IB: max_mr = %d, max_wrs = %d, max_sge = %d, fmr_max_remaps = %d, max_1m_mrs = %d, max_8k_mrs = %d\n", | 
 | 201 | 		 device->attrs.max_fmr, rds_ibdev->max_wrs, rds_ibdev->max_sge, | 
 | 202 | 		 rds_ibdev->fmr_max_remaps, rds_ibdev->max_1m_mrs, | 
 | 203 | 		 rds_ibdev->max_8k_mrs); | 
 | 204 |  | 
 | 205 | 	pr_info("RDS/IB: %s: %s supported and preferred\n", | 
 | 206 | 		device->name, | 
 | 207 | 		rds_ibdev->use_fastreg ? "FRMR" : "FMR"); | 
 | 208 |  | 
 | 209 | 	down_write(&rds_ib_devices_lock); | 
 | 210 | 	list_add_tail_rcu(&rds_ibdev->list, &rds_ib_devices); | 
 | 211 | 	up_write(&rds_ib_devices_lock); | 
 | 212 | 	refcount_inc(&rds_ibdev->refcount); | 
 | 213 |  | 
 | 214 | 	ib_set_client_data(device, &rds_ib_client, rds_ibdev); | 
 | 215 | 	refcount_inc(&rds_ibdev->refcount); | 
 | 216 |  | 
 | 217 | 	rds_ib_nodev_connect(); | 
 | 218 |  | 
 | 219 | put_dev: | 
 | 220 | 	rds_ib_dev_put(rds_ibdev); | 
 | 221 | } | 
 | 222 |  | 
 | 223 | /* | 
 | 224 |  * New connections use this to find the device to associate with the | 
 | 225 |  * connection.  It's not in the fast path so we're not concerned about the | 
 | 226 |  * performance of the IB call.  (As of this writing, it uses an interrupt | 
 | 227 |  * blocking spinlock to serialize walking a per-device list of all registered | 
 | 228 |  * clients.) | 
 | 229 |  * | 
 | 230 |  * RCU is used to handle incoming connections racing with device teardown. | 
 | 231 |  * Rather than use a lock to serialize removal from the client_data and | 
 | 232 |  * getting a new reference, we use an RCU grace period.  The destruction | 
 | 233 |  * path removes the device from client_data and then waits for all RCU | 
 | 234 |  * readers to finish. | 
 | 235 |  * | 
 | 236 |  * A new connection can get NULL from this if its arriving on a | 
 | 237 |  * device that is in the process of being removed. | 
 | 238 |  */ | 
 | 239 | struct rds_ib_device *rds_ib_get_client_data(struct ib_device *device) | 
 | 240 | { | 
 | 241 | 	struct rds_ib_device *rds_ibdev; | 
 | 242 |  | 
 | 243 | 	rcu_read_lock(); | 
 | 244 | 	rds_ibdev = ib_get_client_data(device, &rds_ib_client); | 
 | 245 | 	if (rds_ibdev) | 
 | 246 | 		refcount_inc(&rds_ibdev->refcount); | 
 | 247 | 	rcu_read_unlock(); | 
 | 248 | 	return rds_ibdev; | 
 | 249 | } | 
 | 250 |  | 
 | 251 | /* | 
 | 252 |  * The IB stack is letting us know that a device is going away.  This can | 
 | 253 |  * happen if the underlying HCA driver is removed or if PCI hotplug is removing | 
 | 254 |  * the pci function, for example. | 
 | 255 |  * | 
 | 256 |  * This can be called at any time and can be racing with any other RDS path. | 
 | 257 |  */ | 
 | 258 | static void rds_ib_remove_one(struct ib_device *device, void *client_data) | 
 | 259 | { | 
 | 260 | 	struct rds_ib_device *rds_ibdev = client_data; | 
 | 261 |  | 
 | 262 | 	if (!rds_ibdev) | 
 | 263 | 		return; | 
 | 264 |  | 
 | 265 | 	rds_ib_dev_shutdown(rds_ibdev); | 
 | 266 |  | 
 | 267 | 	/* stop connection attempts from getting a reference to this device. */ | 
 | 268 | 	ib_set_client_data(device, &rds_ib_client, NULL); | 
 | 269 |  | 
 | 270 | 	down_write(&rds_ib_devices_lock); | 
 | 271 | 	list_del_rcu(&rds_ibdev->list); | 
 | 272 | 	up_write(&rds_ib_devices_lock); | 
 | 273 |  | 
 | 274 | 	/* | 
 | 275 | 	 * This synchronize rcu is waiting for readers of both the ib | 
 | 276 | 	 * client data and the devices list to finish before we drop | 
 | 277 | 	 * both of those references. | 
 | 278 | 	 */ | 
 | 279 | 	synchronize_rcu(); | 
 | 280 | 	rds_ib_dev_put(rds_ibdev); | 
 | 281 | 	rds_ib_dev_put(rds_ibdev); | 
 | 282 | } | 
 | 283 |  | 
 | 284 | struct ib_client rds_ib_client = { | 
 | 285 | 	.name   = "rds_ib", | 
 | 286 | 	.add    = rds_ib_add_one, | 
 | 287 | 	.remove = rds_ib_remove_one | 
 | 288 | }; | 
 | 289 |  | 
 | 290 | static int rds_ib_conn_info_visitor(struct rds_connection *conn, | 
 | 291 | 				    void *buffer) | 
 | 292 | { | 
 | 293 | 	struct rds_info_rdma_connection *iinfo = buffer; | 
 | 294 | 	struct rds_ib_connection *ic; | 
 | 295 |  | 
 | 296 | 	/* We will only ever look at IB transports */ | 
 | 297 | 	if (conn->c_trans != &rds_ib_transport) | 
 | 298 | 		return 0; | 
 | 299 | 	if (conn->c_isv6) | 
 | 300 | 		return 0; | 
 | 301 |  | 
 | 302 | 	iinfo->src_addr = conn->c_laddr.s6_addr32[3]; | 
 | 303 | 	iinfo->dst_addr = conn->c_faddr.s6_addr32[3]; | 
 | 304 |  | 
 | 305 | 	memset(&iinfo->src_gid, 0, sizeof(iinfo->src_gid)); | 
 | 306 | 	memset(&iinfo->dst_gid, 0, sizeof(iinfo->dst_gid)); | 
 | 307 | 	if (rds_conn_state(conn) == RDS_CONN_UP) { | 
 | 308 | 		struct rds_ib_device *rds_ibdev; | 
 | 309 |  | 
 | 310 | 		ic = conn->c_transport_data; | 
 | 311 |  | 
 | 312 | 		rdma_read_gids(ic->i_cm_id, (union ib_gid *)&iinfo->src_gid, | 
 | 313 | 			       (union ib_gid *)&iinfo->dst_gid); | 
 | 314 |  | 
 | 315 | 		rds_ibdev = ic->rds_ibdev; | 
 | 316 | 		iinfo->max_send_wr = ic->i_send_ring.w_nr; | 
 | 317 | 		iinfo->max_recv_wr = ic->i_recv_ring.w_nr; | 
 | 318 | 		iinfo->max_send_sge = rds_ibdev->max_sge; | 
 | 319 | 		rds_ib_get_mr_info(rds_ibdev, iinfo); | 
 | 320 | 	} | 
 | 321 | 	return 1; | 
 | 322 | } | 
 | 323 |  | 
 | 324 | #if IS_ENABLED(CONFIG_IPV6) | 
 | 325 | /* IPv6 version of rds_ib_conn_info_visitor(). */ | 
 | 326 | static int rds6_ib_conn_info_visitor(struct rds_connection *conn, | 
 | 327 | 				     void *buffer) | 
 | 328 | { | 
 | 329 | 	struct rds6_info_rdma_connection *iinfo6 = buffer; | 
 | 330 | 	struct rds_ib_connection *ic; | 
 | 331 |  | 
 | 332 | 	/* We will only ever look at IB transports */ | 
 | 333 | 	if (conn->c_trans != &rds_ib_transport) | 
 | 334 | 		return 0; | 
 | 335 |  | 
 | 336 | 	iinfo6->src_addr = conn->c_laddr; | 
 | 337 | 	iinfo6->dst_addr = conn->c_faddr; | 
 | 338 |  | 
 | 339 | 	memset(&iinfo6->src_gid, 0, sizeof(iinfo6->src_gid)); | 
 | 340 | 	memset(&iinfo6->dst_gid, 0, sizeof(iinfo6->dst_gid)); | 
 | 341 |  | 
 | 342 | 	if (rds_conn_state(conn) == RDS_CONN_UP) { | 
 | 343 | 		struct rds_ib_device *rds_ibdev; | 
 | 344 |  | 
 | 345 | 		ic = conn->c_transport_data; | 
 | 346 | 		rdma_read_gids(ic->i_cm_id, (union ib_gid *)&iinfo6->src_gid, | 
 | 347 | 			       (union ib_gid *)&iinfo6->dst_gid); | 
 | 348 | 		rds_ibdev = ic->rds_ibdev; | 
 | 349 | 		iinfo6->max_send_wr = ic->i_send_ring.w_nr; | 
 | 350 | 		iinfo6->max_recv_wr = ic->i_recv_ring.w_nr; | 
 | 351 | 		iinfo6->max_send_sge = rds_ibdev->max_sge; | 
 | 352 | 		rds6_ib_get_mr_info(rds_ibdev, iinfo6); | 
 | 353 | 	} | 
 | 354 | 	return 1; | 
 | 355 | } | 
 | 356 | #endif | 
 | 357 |  | 
 | 358 | static void rds_ib_ic_info(struct socket *sock, unsigned int len, | 
 | 359 | 			   struct rds_info_iterator *iter, | 
 | 360 | 			   struct rds_info_lengths *lens) | 
 | 361 | { | 
 | 362 | 	u64 buffer[(sizeof(struct rds_info_rdma_connection) + 7) / 8]; | 
 | 363 |  | 
 | 364 | 	rds_for_each_conn_info(sock, len, iter, lens, | 
 | 365 | 				rds_ib_conn_info_visitor, | 
 | 366 | 				buffer, | 
 | 367 | 				sizeof(struct rds_info_rdma_connection)); | 
 | 368 | } | 
 | 369 |  | 
 | 370 | #if IS_ENABLED(CONFIG_IPV6) | 
 | 371 | /* IPv6 version of rds_ib_ic_info(). */ | 
 | 372 | static void rds6_ib_ic_info(struct socket *sock, unsigned int len, | 
 | 373 | 			    struct rds_info_iterator *iter, | 
 | 374 | 			    struct rds_info_lengths *lens) | 
 | 375 | { | 
 | 376 | 	u64 buffer[(sizeof(struct rds6_info_rdma_connection) + 7) / 8]; | 
 | 377 |  | 
 | 378 | 	rds_for_each_conn_info(sock, len, iter, lens, | 
 | 379 | 			       rds6_ib_conn_info_visitor, | 
 | 380 | 			       buffer, | 
 | 381 | 			       sizeof(struct rds6_info_rdma_connection)); | 
 | 382 | } | 
 | 383 | #endif | 
 | 384 |  | 
 | 385 | /* | 
 | 386 |  * Early RDS/IB was built to only bind to an address if there is an IPoIB | 
 | 387 |  * device with that address set. | 
 | 388 |  * | 
 | 389 |  * If it were me, I'd advocate for something more flexible.  Sending and | 
 | 390 |  * receiving should be device-agnostic.  Transports would try and maintain | 
 | 391 |  * connections between peers who have messages queued.  Userspace would be | 
 | 392 |  * allowed to influence which paths have priority.  We could call userspace | 
 | 393 |  * asserting this policy "routing". | 
 | 394 |  */ | 
 | 395 | static int rds_ib_laddr_check(struct net *net, const struct in6_addr *addr, | 
 | 396 | 			      __u32 scope_id) | 
 | 397 | { | 
 | 398 | 	int ret; | 
 | 399 | 	struct rdma_cm_id *cm_id; | 
 | 400 | #if IS_ENABLED(CONFIG_IPV6) | 
 | 401 | 	struct sockaddr_in6 sin6; | 
 | 402 | #endif | 
 | 403 | 	struct sockaddr_in sin; | 
 | 404 | 	struct sockaddr *sa; | 
 | 405 | 	bool isv4; | 
 | 406 |  | 
 | 407 | 	isv4 = ipv6_addr_v4mapped(addr); | 
 | 408 | 	/* Create a CMA ID and try to bind it. This catches both | 
 | 409 | 	 * IB and iWARP capable NICs. | 
 | 410 | 	 */ | 
 | 411 | 	cm_id = rdma_create_id(&init_net, rds_rdma_cm_event_handler, | 
 | 412 | 			       NULL, RDMA_PS_TCP, IB_QPT_RC); | 
 | 413 | 	if (IS_ERR(cm_id)) | 
 | 414 | 		return PTR_ERR(cm_id); | 
 | 415 |  | 
 | 416 | 	if (isv4) { | 
 | 417 | 		memset(&sin, 0, sizeof(sin)); | 
 | 418 | 		sin.sin_family = AF_INET; | 
 | 419 | 		sin.sin_addr.s_addr = addr->s6_addr32[3]; | 
 | 420 | 		sa = (struct sockaddr *)&sin; | 
 | 421 | 	} else { | 
 | 422 | #if IS_ENABLED(CONFIG_IPV6) | 
 | 423 | 		memset(&sin6, 0, sizeof(sin6)); | 
 | 424 | 		sin6.sin6_family = AF_INET6; | 
 | 425 | 		sin6.sin6_addr = *addr; | 
 | 426 | 		sin6.sin6_scope_id = scope_id; | 
 | 427 | 		sa = (struct sockaddr *)&sin6; | 
 | 428 |  | 
 | 429 | 		/* XXX Do a special IPv6 link local address check here.  The | 
 | 430 | 		 * reason is that rdma_bind_addr() always succeeds with IPv6 | 
 | 431 | 		 * link local address regardless it is indeed configured in a | 
 | 432 | 		 * system. | 
 | 433 | 		 */ | 
 | 434 | 		if (ipv6_addr_type(addr) & IPV6_ADDR_LINKLOCAL) { | 
 | 435 | 			struct net_device *dev; | 
 | 436 |  | 
 | 437 | 			if (scope_id == 0) { | 
 | 438 | 				ret = -EADDRNOTAVAIL; | 
 | 439 | 				goto out; | 
 | 440 | 			} | 
 | 441 |  | 
 | 442 | 			/* Use init_net for now as RDS is not network | 
 | 443 | 			 * name space aware. | 
 | 444 | 			 */ | 
 | 445 | 			dev = dev_get_by_index(&init_net, scope_id); | 
 | 446 | 			if (!dev) { | 
 | 447 | 				ret = -EADDRNOTAVAIL; | 
 | 448 | 				goto out; | 
 | 449 | 			} | 
 | 450 | 			if (!ipv6_chk_addr(&init_net, addr, dev, 1)) { | 
 | 451 | 				dev_put(dev); | 
 | 452 | 				ret = -EADDRNOTAVAIL; | 
 | 453 | 				goto out; | 
 | 454 | 			} | 
 | 455 | 			dev_put(dev); | 
 | 456 | 		} | 
 | 457 | #else | 
 | 458 | 		ret = -EADDRNOTAVAIL; | 
 | 459 | 		goto out; | 
 | 460 | #endif | 
 | 461 | 	} | 
 | 462 |  | 
 | 463 | 	/* rdma_bind_addr will only succeed for IB & iWARP devices */ | 
 | 464 | 	ret = rdma_bind_addr(cm_id, sa); | 
 | 465 | 	/* due to this, we will claim to support iWARP devices unless we | 
 | 466 | 	   check node_type. */ | 
 | 467 | 	if (ret || !cm_id->device || | 
 | 468 | 	    cm_id->device->node_type != RDMA_NODE_IB_CA) | 
 | 469 | 		ret = -EADDRNOTAVAIL; | 
 | 470 |  | 
 | 471 | 	rdsdebug("addr %pI6c%%%u ret %d node type %d\n", | 
 | 472 | 		 addr, scope_id, ret, | 
 | 473 | 		 cm_id->device ? cm_id->device->node_type : -1); | 
 | 474 |  | 
 | 475 | out: | 
 | 476 | 	rdma_destroy_id(cm_id); | 
 | 477 |  | 
 | 478 | 	return ret; | 
 | 479 | } | 
 | 480 |  | 
 | 481 | static void rds_ib_unregister_client(void) | 
 | 482 | { | 
 | 483 | 	ib_unregister_client(&rds_ib_client); | 
 | 484 | 	/* wait for rds_ib_dev_free() to complete */ | 
 | 485 | 	flush_workqueue(rds_wq); | 
 | 486 | } | 
 | 487 |  | 
 | 488 | static void rds_ib_set_unloading(void) | 
 | 489 | { | 
 | 490 | 	atomic_set(&rds_ib_unloading, 1); | 
 | 491 | } | 
 | 492 |  | 
 | 493 | static bool rds_ib_is_unloading(struct rds_connection *conn) | 
 | 494 | { | 
 | 495 | 	struct rds_conn_path *cp = &conn->c_path[0]; | 
 | 496 |  | 
 | 497 | 	return (test_bit(RDS_DESTROY_PENDING, &cp->cp_flags) || | 
 | 498 | 		atomic_read(&rds_ib_unloading) != 0); | 
 | 499 | } | 
 | 500 |  | 
 | 501 | void rds_ib_exit(void) | 
 | 502 | { | 
 | 503 | 	rds_ib_set_unloading(); | 
 | 504 | 	synchronize_rcu(); | 
 | 505 | 	rds_info_deregister_func(RDS_INFO_IB_CONNECTIONS, rds_ib_ic_info); | 
 | 506 | #if IS_ENABLED(CONFIG_IPV6) | 
 | 507 | 	rds_info_deregister_func(RDS6_INFO_IB_CONNECTIONS, rds6_ib_ic_info); | 
 | 508 | #endif | 
 | 509 | 	rds_ib_unregister_client(); | 
 | 510 | 	rds_ib_destroy_nodev_conns(); | 
 | 511 | 	rds_ib_sysctl_exit(); | 
 | 512 | 	rds_ib_recv_exit(); | 
 | 513 | 	rds_trans_unregister(&rds_ib_transport); | 
 | 514 | 	rds_ib_mr_exit(); | 
 | 515 | } | 
 | 516 |  | 
 | 517 | struct rds_transport rds_ib_transport = { | 
 | 518 | 	.laddr_check		= rds_ib_laddr_check, | 
 | 519 | 	.xmit_path_complete	= rds_ib_xmit_path_complete, | 
 | 520 | 	.xmit			= rds_ib_xmit, | 
 | 521 | 	.xmit_rdma		= rds_ib_xmit_rdma, | 
 | 522 | 	.xmit_atomic		= rds_ib_xmit_atomic, | 
 | 523 | 	.recv_path		= rds_ib_recv_path, | 
 | 524 | 	.conn_alloc		= rds_ib_conn_alloc, | 
 | 525 | 	.conn_free		= rds_ib_conn_free, | 
 | 526 | 	.conn_path_connect	= rds_ib_conn_path_connect, | 
 | 527 | 	.conn_path_shutdown	= rds_ib_conn_path_shutdown, | 
 | 528 | 	.inc_copy_to_user	= rds_ib_inc_copy_to_user, | 
 | 529 | 	.inc_free		= rds_ib_inc_free, | 
 | 530 | 	.cm_initiate_connect	= rds_ib_cm_initiate_connect, | 
 | 531 | 	.cm_handle_connect	= rds_ib_cm_handle_connect, | 
 | 532 | 	.cm_connect_complete	= rds_ib_cm_connect_complete, | 
 | 533 | 	.stats_info_copy	= rds_ib_stats_info_copy, | 
 | 534 | 	.exit			= rds_ib_exit, | 
 | 535 | 	.get_mr			= rds_ib_get_mr, | 
 | 536 | 	.sync_mr		= rds_ib_sync_mr, | 
 | 537 | 	.free_mr		= rds_ib_free_mr, | 
 | 538 | 	.flush_mrs		= rds_ib_flush_mrs, | 
 | 539 | 	.t_owner		= THIS_MODULE, | 
 | 540 | 	.t_name			= "infiniband", | 
 | 541 | 	.t_unloading		= rds_ib_is_unloading, | 
 | 542 | 	.t_type			= RDS_TRANS_IB | 
 | 543 | }; | 
 | 544 |  | 
 | 545 | int rds_ib_init(void) | 
 | 546 | { | 
 | 547 | 	int ret; | 
 | 548 |  | 
 | 549 | 	INIT_LIST_HEAD(&rds_ib_devices); | 
 | 550 |  | 
 | 551 | 	ret = rds_ib_mr_init(); | 
 | 552 | 	if (ret) | 
 | 553 | 		goto out; | 
 | 554 |  | 
 | 555 | 	ret = ib_register_client(&rds_ib_client); | 
 | 556 | 	if (ret) | 
 | 557 | 		goto out_mr_exit; | 
 | 558 |  | 
 | 559 | 	ret = rds_ib_sysctl_init(); | 
 | 560 | 	if (ret) | 
 | 561 | 		goto out_ibreg; | 
 | 562 |  | 
 | 563 | 	ret = rds_ib_recv_init(); | 
 | 564 | 	if (ret) | 
 | 565 | 		goto out_sysctl; | 
 | 566 |  | 
 | 567 | 	rds_trans_register(&rds_ib_transport); | 
 | 568 |  | 
 | 569 | 	rds_info_register_func(RDS_INFO_IB_CONNECTIONS, rds_ib_ic_info); | 
 | 570 | #if IS_ENABLED(CONFIG_IPV6) | 
 | 571 | 	rds_info_register_func(RDS6_INFO_IB_CONNECTIONS, rds6_ib_ic_info); | 
 | 572 | #endif | 
 | 573 |  | 
 | 574 | 	goto out; | 
 | 575 |  | 
 | 576 | out_sysctl: | 
 | 577 | 	rds_ib_sysctl_exit(); | 
 | 578 | out_ibreg: | 
 | 579 | 	rds_ib_unregister_client(); | 
 | 580 | out_mr_exit: | 
 | 581 | 	rds_ib_mr_exit(); | 
 | 582 | out: | 
 | 583 | 	return ret; | 
 | 584 | } | 
 | 585 |  | 
 | 586 | MODULE_LICENSE("GPL"); |