| /***************************************************************************** |
| * Copyright Statement: |
| * -------------------- |
| * This software is protected by Copyright and the information contained |
| * herein is confidential. The software may not be copied and the information |
| * contained herein may not be used or disclosed except with the written |
| * permission of MediaTek Inc. (C) 2016 |
| * |
| * BY OPENING THIS FILE, BUYER HEREBY UNEQUIVOCALLY ACKNOWLEDGES AND AGREES |
| * THAT THE SOFTWARE/FIRMWARE AND ITS DOCUMENTATIONS (""MEDIATEK SOFTWARE"") |
| * RECEIVED FROM MEDIATEK AND/OR ITS REPRESENTATIVES ARE PROVIDED TO BUYER ON |
| * AN ""AS-IS"" BASIS ONLY. MEDIATEK EXPRESSLY DISCLAIMS ANY AND ALL WARRANTIES, |
| * EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF |
| * MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NONINFRINGEMENT. |
| * NEITHER DOES MEDIATEK PROVIDE ANY WARRANTY WHATSOEVER WITH RESPECT TO THE |
| * SOFTWARE OF ANY THIRD PARTY WHICH MAY BE USED BY, INCORPORATED IN, OR |
| * SUPPLIED WITH THE MEDIATEK SOFTWARE, AND BUYER AGREES TO LOOK ONLY TO SUCH |
| * THIRD PARTY FOR ANY WARRANTY CLAIM RELATING THERETO. MEDIATEK SHALL ALSO |
| * NOT BE RESPONSIBLE FOR ANY MEDIATEK SOFTWARE RELEASES MADE TO BUYER'S |
| * SPECIFICATION OR TO CONFORM TO A PARTICULAR STANDARD OR OPEN FORUM. |
| * |
| * BUYER'S SOLE AND EXCLUSIVE REMEDY AND MEDIATEK'S ENTIRE AND CUMULATIVE |
| * LIABILITY WITH RESPECT TO THE MEDIATEK SOFTWARE RELEASED HEREUNDER WILL BE, |
| * AT MEDIATEK'S OPTION, TO REVISE OR REPLACE THE MEDIATEK SOFTWARE AT ISSUE, |
| * OR REFUND ANY SOFTWARE LICENSE FEES OR SERVICE CHARGE PAID BY BUYER TO |
| * MEDIATEK FOR SUCH MEDIATEK SOFTWARE AT ISSUE. |
| * |
| * THE TRANSACTION CONTEMPLATED HEREUNDER SHALL BE CONSTRUED IN ACCORDANCE |
| * WITH THE LAWS OF THE STATE OF CALIFORNIA, USA, EXCLUDING ITS CONFLICT OF |
| * LAWS PRINCIPLES. ANY DISPUTES, CONTROVERSIES OR CLAIMS ARISING THEREOF AND |
| * RELATED THERETO SHALL BE SETTLED BY ARBITRATION IN SAN FRANCISCO, CA, UNDER |
| * THE RULES OF THE INTERNATIONAL CHAMBER OF COMMERCE (ICC). |
| * |
| *****************************************************************************/ |
| /************************************************************************* |
| * |
| * File Name: valattune.h |
| * |
| * Description: Tuning parameters |
| * |
| * |
| ************************************************************************/ |
| #ifndef _AT_TUNE_H |
| #define _AT_TUNE_H 1 |
| |
| #include "valatdata.h" |
| /* --------------------------------------------------------------------- |
| * Name: Data Port Present |
| * |
| * Description: |
| * This switch defines whether or not AppInt supports a Data Port |
| * interface. Set this switch to KAL_FALSE for Browser-Only applications. |
| * |
| * Restrictions: |
| * KAL_FALSE, KAL_TRUE |
| * |
| * Default Value: |
| * KAL_TRUE |
| * |
| * Notes: |
| * When this switch is set to KAL_FALSE, the following files can be excluded |
| * from the build-set: |
| * - ai_ch.c |
| * - ai_cmd.c |
| * - ai_dh.c |
| * - ai_dr.c |
| * - ai_parse.c |
| * - atparse.c |
| * - atpparse.c |
| * - iqmgr.c |
| * - isolib.c |
| */ |
| #define AT_DPD_PRESENT 1 |
| |
| /* --------------------------------------------------------------------- |
| * Name: V.42bis Compression Capabilities: <direction> |
| * |
| * Description: |
| * This switch defines the capabilities of the V.42bis software |
| * provisioned in the MT. AppInt uses this switch to determine the |
| * valid range for the <direction> parameter in the +CDS command. |
| * |
| * Restrictions: |
| * 0: No V.42bis provisioned. |
| * 1: V.42bis available in the reverse direction only. |
| * 2: V.42bis available in the forward direction only. |
| * 3: V.42bis available in both directions. |
| * |
| * Default Value: |
| * 0 |
| */ |
| #define AT_CMP_DIRECTION 0 |
| |
| /* --------------------------------------------------------------------- |
| * Name: V.42bis Compression Capabilities: <max_dict> |
| * |
| * Description: |
| * This switch defines the maximum dictionary size supported the V.42bis |
| * software provisioned in the MT. AppInt uses this switch to determine |
| * the valid range for the <max_dict> parameter in the +CDS command. |
| * |
| * Restrictions: |
| * 512 - 65535 |
| * |
| * Default Value: |
| * 2048 |
| */ |
| #define AT_CMP_MAX_DICT 2048 |
| |
| |
| /* --------------------------------------------------------------------- |
| * Name: V.42bis Compression Capabilities: <max_string> |
| * |
| * Description: |
| * This switch defines the maximum string size supported the V.42bis |
| * software provisioned in the MT. AppInt uses this switch to determine |
| * the valid range for the <max_string> parameter in the +CDS command. |
| * |
| * Restrictions: |
| * 6 - 250 |
| * |
| * Default Value: |
| * 6 |
| */ |
| #define AT_CMP_MAX_STRING 6 |
| |
| |
| /* --------------------------------------------------------------------- |
| * Name: Data Port Driver Capabilities: autobaud rates |
| * |
| * Description: |
| * This switch defines the bit rates which may be auto-detected by the |
| * Data Port Driver hardware. These rates are to be used in Command |
| * state and for Async Data calls only. AppInt uses this switch to |
| * determine the valid range for the <auto-detectable rates> parameter |
| * in the +IPR command. |
| * |
| * Restrictions: |
| * Any number of entries from the following list: |
| * BR_300 |
| * BR_1200 |
| * BR_2400 |
| * BR_4800 |
| * BR_9600 |
| * BR_19200 |
| * BR_38400 |
| * BR_57600 |
| * BR_115200 |
| * or: BR_NONE. |
| * |
| * The same bit rate may not be specified in both AT_DPD_AUTOBAUD_RATES and |
| * AT_DPD_FIXED_RATES. |
| * |
| * Default Value: |
| * (BR_300 + BR_1200 + BR_2400 + BR_4800 + BR_9600 + |
| * BR_19200 + BR_38400 + BR_57600 + BR_115200) |
| */ |
| /* |
| #define AT_DPD_AUTOBAUD_RATES (BR_300 + \ |
| BR_1200 + \ |
| BR_2400 + \ |
| BR_4800 + \ |
| BR_9600 + \ |
| BR_19200 + \ |
| BR_38400 + \ |
| BR_57600 + \ |
| BR_115200) |
| |
| */ |
| |
| #define AT_DPD_AUTOBAUD_RATES BR_NONE |
| /* --------------------------------------------------------------------- |
| * Name: Data Port Driver Capabilities: fixed baud rates |
| * |
| * Description: |
| * This switch defines the bit rates supported by the Data Port Driver |
| * hardware, but which may not be auto-detected. |
| * These rates are to be used in Command state and for Async Data calls only. |
| * AppInt uses this switch to determine the valid range for the |
| * <fixed-only rates> parameter in the +IPR command. |
| * |
| * Restrictions: |
| * Any number of entries from the following list: |
| * BR_300 |
| * BR_1200 |
| * BR_2400 |
| * BR_4800 |
| * BR_9600 |
| * BR_19200 |
| * BR_38400 |
| * BR_57600 |
| * BR_115200 |
| * or: BR_NONE |
| * |
| * The same bit rate may not be specified in both AT_DPD_AUTOBAUD_RATES and |
| * AT_DPD_FIXED_RATES. |
| * |
| * Default Value: |
| * BR_NONE |
| */ |
| #define AT_DPD_FIXED_RATES (BR_19200 + \ |
| BR_115200+ \ |
| BR_230400 ) |
| |
| |
| /* --------------------------------------------------------------------- |
| * Name: Local AT-Parameter Default Value: +IPR |
| * |
| * Description: |
| * This switch defines the default value to be used for the "Fixed |
| * DTE Rate" parameter. |
| * This value is used to reset the parameter value when a ATZ or AT&F |
| * command is processed and AT_DPD_AUTOBAUD_RATES is BR_NONE. Otherwise, |
| * a value of zero is used. |
| * |
| * Restrictions: |
| * Any value from the list defined for AT_DPD_FIXED_RATES. |
| * |
| * Default Value: |
| * BR_230400 |
| */ |
| #define AT_DEFAULT_IPR BR_230400 |
| |
| |
| /* --------------------------------------------------------------------- |
| * Name: Data Port Driver Capabilities: Maximum FAX bit rate |
| * |
| * Description: |
| * This switch defines the maximum bit rate which the Data Port Driver |
| * can use during FAX calls. AppInt uses this switch to determine the |
| * valid range of values for the +FPR command. |
| * |
| * Restrictions: |
| * Any one of the following values: |
| * FR_2400 |
| * FR_4800 |
| * FR_9600 |
| * FR_19200 |
| * FR_38400 |
| * FR_57600 |
| * FR_115200 |
| * |
| * Default Value: |
| * FR_19200 |
| */ |
| #define AT_DPD_MAX_FPR FR_19200 |
| |
| |
| /* --------------------------------------------------------------------- |
| * Name: Data Port Driver Capabilities: Fax transmit buffer size. |
| * |
| * Description: |
| * This switch defines the size of the buffer used by the Data Port Driver |
| * to store data in the reverse direction during FAX calls. AppInt uses |
| * this switch when reporting information for the <tbs> parameter in the |
| * +FBS? command. |
| * |
| * Restrictions: |
| * 0 - 65535 |
| * |
| * Default Value: |
| * 3600 |
| */ |
| #define AT_DPD_FBS_TX 3600 |
| |
| /* --------------------------------------------------------------------- |
| * Name: Data Port Driver capabilities: Fax receive buffer size. |
| * |
| * Description: |
| * This switch defines the size of the buffer used by the Data Port Driver |
| * to store data received in the forward direction during FAX calls. |
| * AppInt uses this switch when reporting information for the <rbs> |
| * parameter in the +FBS? command. |
| * |
| * Restrictions: |
| * 3600 - 65535 |
| * |
| * Default Value: |
| * 3600 |
| */ |
| #define AT_DPD_FBS_RX 3600 |
| |
| /* --------------------------------------------------------------------- |
| * Name: Local AT-Parameter Default Value: +CDS.<max_dict> |
| * |
| * Description: |
| * This switch defines the default value to be used for the V.42bis |
| * data compression: <max_dict> parameter to be used on the Um interface. |
| * This value is used to reset the parameter value when a ATZ or AT&F |
| * command is processed. |
| * |
| * Restrictions: |
| * 512 - AT_CMP_MAX_DICT |
| * |
| * Default Value: |
| * AT_CMP_MAX_DICT |
| */ |
| #define AT_DEFAULT_CDS_MAX_DICT AT_CMP_MAX_DICT |
| |
| |
| /* --------------------------------------------------------------------- |
| * Name: Local AT-Parameter Default Value: +CPS |
| * |
| * Description: |
| * This switch defines the default value to be used for the |
| * Packet Data Service Option parameter. |
| * This value is used to reset the parameter value when a ATZ or AT&F |
| * command is processed. |
| * |
| * Restrictions: |
| * 7, 8, 15, 16, 22, 23, 24, 25, 26, 27, 28, 29, |
| * 4103, 4104 |
| * |
| * Default Value: |
| * 4103 |
| */ |
| #define AT_DEFAULT_CPS 59 |
| |
| /* --------------------------------------------------------------------- |
| * Name: Local AT-Parameter Default Value: +CMUX |
| * |
| * Description: |
| * This switch defines the default value to be used for the "Select |
| * Multiplex Option" parameter. |
| * This value is used to reset the parameter value when a ATZ or AT&F |
| * command is processed. |
| * |
| * Restrictions: |
| * 1 - 2 |
| * |
| * Default Value: |
| * 2 |
| */ |
| #define AT_DEFAULT_CMUX 2 |
| |
| /* --------------------------------------------------------------------- |
| * Name: Local AT-Parameter Default Value: +FPR |
| * |
| * Description: |
| * This switch defines the default value to be used for the "Serial |
| * Port Rate Control" parameter. |
| * This value is used to reset the parameter value when a ATZ or AT&F |
| * command is processed and +FCLASS = 2.0. |
| * |
| * Restrictions: |
| * Any value from the following list up to the value specified by |
| * AT_DPD_MAX_FPR: |
| * FR_AUTOBAUD, |
| * FR_19200 |
| * |
| * Default Value: |
| * FR_AUTOBAUD |
| */ |
| #define AT_DEFAULT_FPR FR_19200 |
| |
| /* --------------------------------------------------------------------- |
| * Name: NSPE Capabilities: Maximum TX Request Size |
| * |
| * Description: |
| * This switch defines the maximum size (in bytes) which AppInt may |
| * specify in a nspeAiTxReq call. AppInt requires this parameter to |
| * be at least 98 bytes so that the longest EIA-617 in-band command |
| * may be transmitted in a single TxReq. The upper bound for this |
| * parameter is determined by the MBUF size and high water mark settings |
| * configured for NSPE. |
| * |
| * Restrictions: |
| * 98 - 65535 |
| * |
| * Default Value: |
| * 1024 |
| */ |
| #define AT_NSPE_MAX_TXREQ_LEN 1024 |
| |
| |
| /* --------------------------------------------------------------------- |
| * Name: Data Transfer Behavior |
| * |
| * Description: |
| * This switch defines the maximum amount of time (in msec) AppInt will |
| * allow reverse channel User Data to sit in the V.42bis compressor or |
| * the TCP layer of NSPE. When this timer expires, AppInt will flush the |
| * compressor (if compression is active and if there could be partially |
| * matched User Data strings in the compressor) and push data out of the |
| * TCP layer. |
| * |
| * Restrictions: |
| * 1 - 65535 |
| * |
| * Default Value: |
| * 100 |
| */ |
| #define AT_STALE_DATA_TMO 100 |
| |
| |
| /* --------------------------------------------------------------------- |
| * Name: AppInt Capabilities: Maximum AT-command line length |
| * |
| * Description: |
| * This switch defines the maximum size of an AT-command line in |
| * COMMAND state as well as the largest single AT-command which may be |
| * reflected by the IWF in ONLINE state. |
| * |
| * For COMMAND state, this size includes the initial "AT" and trailing |
| * <s3><s4> characters. |
| * |
| * The longest single AT-command in the IS-707 repertoire (AT+FNS=) requires |
| * 280 characters. The second longest command (AT+CFG=) requires 258 |
| * characters. AppInt allows the data from repetitive AT+FNS= and AT+CFG= |
| * commands to be appended to the existing parameter data. Therefore, with |
| * a cooperating TE2, this tuning parameter may be safely reduced to the |
| * maximum length of the third longest single AT-command: AT+MA= |
| * (48 characters). |
| * |
| * Restrictions: |
| * 48 - 65535 |
| * |
| * Default Value: |
| * 280 |
| */ |
| #ifdef SYS_OPTION_ENHANCEDAT |
| #define AT_MAX_AT_CMD_LEN ATC_ENHANCED_AT_CMD_LEN |
| #else |
| #define AT_MAX_AT_CMD_LEN 280 |
| #endif |
| |
| |
| /* --------------------------------------------------------------------- |
| * Name: Compression Negotiation Timeout |
| * |
| * Description: |
| * This switch defines the amount of time (in msec) AppInt will wait for |
| * the Um data compression negotiation procedure to complete. |
| * This timer is activated only if the +CDS.<compressionNegotiation> |
| * parameter is enabled. |
| * If the timer expires and the data compression specified by the other |
| * +CDS parameters has not been obtained, AppInt will disconnect the call. |
| * |
| * Restrictions: |
| * 1 - 65535 |
| * |
| * Default Value: |
| * 5000 |
| */ |
| #define AT_CN_TMO 5000 |
| |
| /* --------------------------------------------------------------------- |
| * Name: Allow Invalid Body Characters |
| * |
| * Description: |
| * Setting this switch to KAL_TRUE disables EIA-617 extended command body |
| * character validation. This overcomes a bug in some IWF implementations. |
| * |
| * Restrictions: |
| * KAL_FALSE, KAL_TRUE |
| * |
| * Default Value: |
| * KAL_TRUE |
| */ |
| #define AT_ALLOW_INVALID_BODY_CHARS KAL_TRUE |
| |
| /* --------------------------------------------------------------------- |
| * Name: Allow Invalid Body Characters |
| * |
| * Description: |
| * This switch determines whether or not AppInt will upload an ATM1 |
| * (speaker-on-until-connect) command to the IWF. |
| * This switch should only be set to KAL_TRUE if the MT software supports |
| * the multiply connected service option configuration and service |
| * option switching functions described in IS-707-A.4, section 4.1(b) |
| * |
| * Restrictions: |
| * KAL_FALSE, KAL_TRUE |
| * |
| * Default Value: |
| * KAL_FALSE |
| */ |
| #define AT_UPLOAD_ATM KAL_FALSE |
| |
| /* --------------------------------------------------------------------- |
| * Name: Packet Data Service Options |
| * |
| * Description: |
| * These switches define the values which AppInt will accept for |
| * the +CPS AT-command. |
| * |
| * Restrictions: |
| * KAL_FALSE, KAL_TRUE |
| * |
| * Default Value: |
| * AT_CPS_SO_07: KAL_TRUE |
| * AT_CPS_SO_08: KAL_TRUE |
| * AT_CPS_SO_15: KAL_TRUE |
| * AT_CPS_SO_16: KAL_TRUE |
| * |
| * AT_CPS_SO_22: KAL_FALSE |
| * AT_CPS_SO_23: KAL_FALSE |
| * AT_CPS_SO_24: KAL_FALSE |
| * AT_CPS_SO_25: KAL_FALSE |
| * AT_CPS_SO_26: KAL_FALSE |
| * AT_CPS_SO_27: KAL_FALSE |
| * AT_CPS_SO_28: KAL_FALSE |
| * AT_CPS_SO_29: KAL_FALSE |
| * |
| * AT_CPS_SO_4103: KAL_TRUE |
| * AT_CPS_SO_4104: KAL_TRUE |
| */ |
| #define AT_CPS_SO_07 KAL_TRUE |
| #define AT_CPS_SO_08 KAL_TRUE |
| #define AT_CPS_SO_15 KAL_TRUE |
| #define AT_CPS_SO_16 KAL_TRUE |
| |
| #define AT_CPS_SO_22 KAL_TRUE |
| #define AT_CPS_SO_23 KAL_TRUE |
| #define AT_CPS_SO_24 KAL_TRUE |
| #define AT_CPS_SO_25 KAL_TRUE |
| |
| #define AT_CPS_SO_26 KAL_FALSE |
| #define AT_CPS_SO_27 KAL_FALSE |
| #define AT_CPS_SO_28 KAL_FALSE |
| #define AT_CPS_SO_29 KAL_FALSE |
| |
| #define AT_CPS_SO_33 KAL_TRUE |
| #define AT_CPS_SO_59 KAL_TRUE |
| #define AT_CPS_SO_69 KAL_TRUE |
| |
| #define AT_CPS_SO_4103 KAL_TRUE |
| #define AT_CPS_SO_4104 KAL_TRUE |
| |
| |
| /* --------------------------------------------------------------------- |
| * Name: Maximum Browser Digits |
| * |
| * Description: |
| * This switch defines the maximum string length which can be returned by |
| * the cfgAiGetBrowserDigits function, excluding the NULL terminator. |
| * |
| * Restrictions: |
| * 1 - 255 |
| * |
| * Default Value: |
| * 20 |
| */ |
| #define AT_MAX_BROWSER_DIGITS 20 |
| |
| #ifdef MTK_CBP |
| /* --------------------------------------------------------------------- |
| * Name: SYS ACTIVED BAND |
| * |
| * Default Value: |
| * VAL_SYS_BAND_CLASS_INVALID_MASK 0XFFFF FFFF |
| */ |
| |
| #define AT_DEFAULT_SYS_ACTIVED_BAND_CLASS_MASK 0XFFFFFFFF |
| #endif |
| |
| #endif /* _AI_TUNE_H */ |